QM1004-0.5-18 Combined RF Upconverter/Downconverter
User Manual
5.5 SYSTem:LOADstate [0-5]
This command restores a previously saved state from non-volatile memory. In addition to factory default
state 0, there are 5 re-writeable memory locations, specified by choosing an index between 1 and 5.
The restored parameters are the
RF Power State, Reference Frequency, External LO1 Enabled, External
LO1 Switch Override, External LO2 Enabled, External LO2 Switch Override, External Reference Enabled,
External Referece Switch Override, Tune Frequency, Upconverter Bypass Enabled, Upconverter LNA
Power State, Upconverter Attenuation 1, Upconverter Attenuation 2, Upconverter ASR State, Downcon-
verter Bypass Enabled, Downconverter LNA Power State, and Downconverter Attenuation
. For a detailed
description of the parameters saved, see the relevent command descriptions in this manual. When the
SYSTem:LOADstate command is called, these parameters will be applied to the device.
Syntax
:
SYST
:
LOAD
Space
0-5
?
There are 6 memory locations, numbered 0 through 5. Memory location 0 contains the factory default
settings, while locations 1-5 are user re-writeable using SYSTem:SAVEstate.
Example
:SYST:LOAD 4
This command loads the state 4 parameters from non-volatile memory and applies
them to the device.
Error Message
If the parameter is not in the recognized format, error
-102, "Syntax error"
occurs.
If the parameter is less than 0 or greater than 5, error
-222, "Data out of range"
occurs.
Quonset Microwave
Revision 1.2.1
68
Содержание QM1004-0.5-18
Страница 7: ...QM1004 0 5 18 Combined RF Upconverter Downconverter User Manual Quonset Microwave Revision 1 2 1 vi...
Страница 15: ...QM1004 0 5 18 Combined RF Upconverter Downconverter User Manual Quonset Microwave Revision 1 2 1 4...
Страница 40: ...QM1004 0 5 18 Combined RF Upconverter Downconverter User Manual 6 14 WAI 89 Quonset Microwave Revision 1 2 1 29...
Страница 105: ...Quonset Microwave www quonsetmicrowave com 1004 011 21 1004 011 21 Revision 1 2 1 November 2022...