Quirky ISO Скачать руководство пользователя страница 6

ISO

  

|

  6

SAFETY INFORMATION

READ AND SAVE THESE INSTRUCTIONS
Please read and understand the entire manual before attempting 
to assemble, operate, or install the product.

•  Always disconnect the power supply prior to servicing the fan, 

motor, or junction box.

•  Installation work must be carried out by a qualified person(s) in 

accordance to all local and safety codes, including the rules for 
fire-rated construction.

•  Follow all local building, safety, and electrical codes as well 

as NEC (National Electrical Code) and OSHA (Occupational 
Safety and Health Act).

•  Electric Service supply must be 120 volts, 60 hertz.

•  This unit must be properly grounded.

•  Do not bend or kink the power wires.

•  Exercise care to not damage existing wiring when cutting  

or drilling into walls or ceilings.

•  Sufficient air supply is required for proper combustion 

and exhaustion of gases through the chimney (flue), 
or fuel burning equipment, to prevent back-drafting. 
*See the standards of NFPA (National Fire Protection 
Association) and ASHRAE (American Society for 
Heating Refrigeration and Air Conditioning Engineers) 
and the local building code authorities.

• 

WARNING 

– To reduce the risk of fire or electric shock – do 

not use this fan with any solid state control device, such as a 
remote control, dimmer switch, or certain timers. Mechanical 
timers are not solid state devices.

•  Do not install in a cooking area.

• 

CAUTION

 – For general ventilating use only – do not use to 

exhaust hazardous or explosive vapors.

•  Fans should always be vented to the exterior in compliance 

with local codes.

•  Do not install in a ceiling with insulation greater than R42.

•  Ductwork should be installed in a straight line  

with minimal bends.

•  Ductwork size must be the same size as the discharge 

and should not be reduced. Reducing the duct size may 
increase fan noise.

•  Prior to servicing or cleaning this unit, shut off power supply 

at the panel and lock to prevent the power from being turned 
on. If the panel cannot be locked, clearly mark the panel with a 
warning tag to prevent the power from being turned on.

•  Use this unit in the manner intended by the manufacturer. 

•  WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC 

SHOCK, OR INJURY TO PERSONS, OBSERVE THE 
FOLLOWING: 
 
a) Use this unit only in the manner intended by the manufacturer. 
If you have questions, contact the manufacturer. 
 
b) Before servicing or cleaning unit, switch power off at service 
panel and lock the service disconnecting means to prevent 
power from being switched on accidentally. When the service 
disconnecting means cannot be locked, securely fasten a 
prominent warning device, such as a tag, to the service panel.

•  If you have any questions please call customer service at 

1-866-5QUIRKY (1-866-578-4759).

Содержание ISO

Страница 1: ...ilateur aspirant activ par la vapeur et veilleuse activ e par le mouvement extractor extractor activado por vapor y luz nocturna activada por movimiento ISO For service questions contact Quirky at 1 8...

Страница 2: ...ISO 2...

Страница 3: ...BOX SAFETY INFORMATION PREPARATION WIRING INSTRUCTIONS INSTALLATION INSTRUCTIONS NEW CONSTRUCTION EXISTING CONSTRUCTION WALL SWITCH SPECIFICATIONS CARE AND MAINTENANCE TROUBLESHOOTING WARRANTY UL507...

Страница 4: ...SPECIFICATIONS Grill dimensions 13 x 13 x 1 5 33 cm x 33 cm x 3 8 cm Housing dimensions 97 8 x 97 8 x 8 25 1 cm x 25 1 cm x 20 3 cm Duct diameter 4 10 2 cm Sound output 1 3 sones Airflow 90 CFM Exhau...

Страница 5: ...ng wood screw 6 actual size short machine screw 4 actual size long machine screw 2 actual size switch suspension bracket II suspension bracket III metal rim and glass bell ceiling plate IN THE BOX NOT...

Страница 6: ...control dimmer switch or certain timers Mechanical timers are not solid state devices Do not install in a cooking area CAUTION For general ventilating use only do not use to exhaust hazardous or explo...

Страница 7: ...rdware store The hole for installation is not sized to the fan unit use the following dimensions so that the Iso ceiling panel will rest flush against the ceiling DIMENSION REQUIREMENTS Ceiling Openin...

Страница 8: ...n s in accordance with all applicable codes and standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burn...

Страница 9: ...BOARD CEILING BOARD JOIST BRACKET 5 Using wire nuts provided connect house wires to ventilating fan wires black to black white to white green to green refer to wiring diagram on page 7 CAUTION If you...

Страница 10: ...housing EXISTING CONSTRUCTION 2 Make sure the existing hole is at least 10 x 10 25 4 cm x 25 4 cm but smaller than 13 x 13 33 cm x 33 cm 3 Cut into the ceiling about 2 5 cm wide to fit drill bit refer...

Страница 11: ...al wire which is white and potentially a grounding wire which is green or bare copper There may be other wires in the switch box but you are only dealing with the ones connected directly to the switch...

Страница 12: ...use solvents thinner or harsh chemicals for cleaning the fan Do not allow water to enter the motor Do not immerse plastic parts in water over 140 F 60 C 1 Unscrew the four 4 screws and carefully remov...

Страница 13: ...cloth with dish detergent wipe the fan housing and dry with a cloth DO NOT USE abrasive cloth steel wool pads or scouring pads 3 Replace the ceiling panel by following steps 7 13 under installation i...

Страница 14: ...n 18 45 7 cm to the fan discharge Fan body not securely attached Be sure the fan is securely attached to your ceiling joists Fan duct is being obstructed at some point including end of duct Check the...

Страница 15: ...Night light sensor is not registering movement Using a damp cloth or rag clean off fan s faceplate including the small half sphere sensor Make sure the hanging part of the unit is not obstructing the...

Страница 16: ...implied warranties or incidental consequential or other damages so the above exclusions and limitations may not apply to you This device complies with Part 15 of the FCC Rules Operation is subject to...

Страница 17: ...ection 64A Installation Instructions WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Installation work and electrical wiring must be done by qualified pe...

Страница 18: ...or service and support email us at questions quirky com or call 1 866 5QUIRKY 1 866 578 4759 R INS ISO1 X rev073014 For service questions contact Quirky at 1 866 578 4759 For sales inquiries contact S...