Quirky ISO Скачать руководство пользователя страница 17

ISO

  

|

  17

UL507 WARNING STATEMENT
Section 64 – General

READ AND SAVE THESE INSTRUCTIONS

1 Prevent a risk of fire, electric shock, or injury to persons, 

by cleaning and user maintenance, such as lubrication.

2 Unplug or disconnect the appliance from the power supply 

before servicing.

3  WARNING To Reduce The Risk Of Fire Or Electric  

Shock, Do Not Use This Fan With Any Solid State Speed 
Control Device.

4 WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC 

SHOCK, OR INJURY TO PERSONS, OBSERVE THE 
FOLLOWING:

 a) Use this unit only in the manner intended by the 

manufacturer. If you have questions, contact the 
manufacturer.

 b) Before servicing or cleaning unit, switch power off at 

service panel and lock the service disconnecting means to 
prevent power from being switched on accidentally. When 
the service disconnecting means cannot be locked, securely 
fasten a prominent warning device, such as a tag, to the 
service panel.

5 CAUTION – For General Ventilating Use Only. Do Not Use 

To Exhaust Hazardous Or Explosive Materials And Vapors.

 

Additional safety information is included in the instruction 
manual on page 6.

UL507 WARNING STATEMENT
Section 64A – Installation Instructions

WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, 
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

  a) Installation work and electrical wiring must be done by 

qualified person(s) in accordance with all applicable codes  
and standards, including fire rated construction.

  b) Sufficient air is needed for proper combustion and 

exhausting of gases through the flue (chimney) of fuel burning 
equipment to prevent back drafting. Follow the heating 
equipment manufacturer’s guideline and safety standards 
such as those published by the National Fire Protection 
Association (NFPA), and the American Society for Heating, 
Refrigeration and Air Conditioning Engineers (ASHRAE),  
and the local code authorities.

  c) When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities.

  d) Ducted fans must always be vented to the outdoors.

  e) If this unit is to be installed over a tub or shower, it must be 

marked as appropriate for the application and be connected 
to a GFCI (Ground Fault Circuit Interrupter) – protected 
branch circuit.

Additional installation instructions are included in the instruction 
manual on pages 8–11.

UL507 WARNING STATEMENT
Section 64B – User Servicing Instructions

All user servicing instructions are included in the instruction 
manual on pages 12–13.

Содержание ISO

Страница 1: ...ilateur aspirant activ par la vapeur et veilleuse activ e par le mouvement extractor extractor activado por vapor y luz nocturna activada por movimiento ISO For service questions contact Quirky at 1 8...

Страница 2: ...ISO 2...

Страница 3: ...BOX SAFETY INFORMATION PREPARATION WIRING INSTRUCTIONS INSTALLATION INSTRUCTIONS NEW CONSTRUCTION EXISTING CONSTRUCTION WALL SWITCH SPECIFICATIONS CARE AND MAINTENANCE TROUBLESHOOTING WARRANTY UL507...

Страница 4: ...SPECIFICATIONS Grill dimensions 13 x 13 x 1 5 33 cm x 33 cm x 3 8 cm Housing dimensions 97 8 x 97 8 x 8 25 1 cm x 25 1 cm x 20 3 cm Duct diameter 4 10 2 cm Sound output 1 3 sones Airflow 90 CFM Exhau...

Страница 5: ...ng wood screw 6 actual size short machine screw 4 actual size long machine screw 2 actual size switch suspension bracket II suspension bracket III metal rim and glass bell ceiling plate IN THE BOX NOT...

Страница 6: ...control dimmer switch or certain timers Mechanical timers are not solid state devices Do not install in a cooking area CAUTION For general ventilating use only do not use to exhaust hazardous or explo...

Страница 7: ...rdware store The hole for installation is not sized to the fan unit use the following dimensions so that the Iso ceiling panel will rest flush against the ceiling DIMENSION REQUIREMENTS Ceiling Openin...

Страница 8: ...n s in accordance with all applicable codes and standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burn...

Страница 9: ...BOARD CEILING BOARD JOIST BRACKET 5 Using wire nuts provided connect house wires to ventilating fan wires black to black white to white green to green refer to wiring diagram on page 7 CAUTION If you...

Страница 10: ...housing EXISTING CONSTRUCTION 2 Make sure the existing hole is at least 10 x 10 25 4 cm x 25 4 cm but smaller than 13 x 13 33 cm x 33 cm 3 Cut into the ceiling about 2 5 cm wide to fit drill bit refer...

Страница 11: ...al wire which is white and potentially a grounding wire which is green or bare copper There may be other wires in the switch box but you are only dealing with the ones connected directly to the switch...

Страница 12: ...use solvents thinner or harsh chemicals for cleaning the fan Do not allow water to enter the motor Do not immerse plastic parts in water over 140 F 60 C 1 Unscrew the four 4 screws and carefully remov...

Страница 13: ...cloth with dish detergent wipe the fan housing and dry with a cloth DO NOT USE abrasive cloth steel wool pads or scouring pads 3 Replace the ceiling panel by following steps 7 13 under installation i...

Страница 14: ...n 18 45 7 cm to the fan discharge Fan body not securely attached Be sure the fan is securely attached to your ceiling joists Fan duct is being obstructed at some point including end of duct Check the...

Страница 15: ...Night light sensor is not registering movement Using a damp cloth or rag clean off fan s faceplate including the small half sphere sensor Make sure the hanging part of the unit is not obstructing the...

Страница 16: ...implied warranties or incidental consequential or other damages so the above exclusions and limitations may not apply to you This device complies with Part 15 of the FCC Rules Operation is subject to...

Страница 17: ...ection 64A Installation Instructions WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Installation work and electrical wiring must be done by qualified pe...

Страница 18: ...or service and support email us at questions quirky com or call 1 866 5QUIRKY 1 866 578 4759 R INS ISO1 X rev073014 For service questions contact Quirky at 1 866 578 4759 For sales inquiries contact S...

Отзывы: