background image

Model: 

5250

DF

Dual Fuel Generator

O

PERATOR’S MANUAL

SAVE THIS MANUAL FOR FUTURE REFERENCE

This manual contains important information regarding safety, operation, and maintenance.

CPO Commerce, LLC

60 Crestridge DR

Suwanee, GA  30024

Customer

 service#: 1-866-577-3014

EMAIL: [email protected]

Содержание 5250DF

Страница 1: ...AL SAVE THIS MANUAL FOR FUTURE REFERENCE This manual contains important information regarding safety operation and maintenance CPO Commerce LLC 60 Crestridge DR Suwanee GA 30024 Customer service 1 866...

Страница 2: ...Gui d elines 4 Genera a al 3 4 12 13 21 22 24 25 26 29 al Precautions General Parts Operation Inspection Cleaning and Maintenance Installation Wiring iagram roubles ooting T h D Specifications 2 5250W...

Страница 3: ...re to retain them for future use WARNING WARNINGS INDICATE A CERTAINTY OR STRONG POSSIBILITY OF PERSONAL INJURY OR DEATH IF INSTRUCTIONS ARE NOT FOLLOWED CAUTION CAUTIONS INDICATE A POSSIBILITY OF EQU...

Страница 4: ...S EXTREMELY FLAMMABLE AND IS EXPLOSIVE UNDER CERTAIN CONDITIONS KEEP OUT OF REACH OF CHILDREN Gasoline fuel and fumes are flammable and potentially explosive Use proper fuel storage and handling proce...

Страница 5: ...f this occurs open exhaust system drain plugs if equipped and allow the gases to dissipate before attempting to restart the generator Hot Components Power Output This generator is not designed to powe...

Страница 6: ...e one blade is wider than the other This plug fits in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electri...

Страница 7: ...racteristics and rated capacities of the generator Before servicing equipment powered by the generator disconnect the equipment from its power input Keep all electrical equipment clean and dry Replace...

Страница 8: ...y generator that cannot be controlled with the power switch is dangerous and must be replaced Generator Use and Care Make sure the power switch is in its OFF position and disconnect the spark plug wir...

Страница 9: ...cian and building contractor All electrical work including the earth ground connection should be completed by a licensed electrician Any separate fuel storage or generator supply facility must be buil...

Страница 10: ...s etc Install sound and weather proofing only when it is not raining or snowing to avoid trapping moisture within the generator s area Mechanical Always make sure the power switch is in its OFF positi...

Страница 11: ...les and safety hat Do not alter or adjust any part of the generator that is assembled and supplied by the manufacturer Always follow and complete scheduled engine and generator maintenance Chemicals A...

Страница 12: ...meter AC 120 240V 30A Receptacle AC 120V 20A Duplex Grounding terminal 12 Fuel tank cap Fuel tank Frame Control Panel Fuel valve Recoil starter Oil dipstick Wheel Air filter Choke lever One way valve...

Страница 13: ...MARKED LINE ON THE DIPSTICK THEN SCREW THE DIPSTICK BACK INTO THE OIL FILL HOLE Before Starting the Generator 1 Check that the engine power switch is in the OFF position 2 Before the first use remove...

Страница 14: ...qualified electrician Ground Terminal Symbol The 5250Watt dual fuel generator can be started using the following method Recoil Start Method IF USING PROPANE FUEL SOURCE 1 Connect the gas pipe to the...

Страница 15: ...nect all devices from the outlets on the generator panel 2 Press the engine switch to the ON position 3 Grasp the recoil starter handle and pull it until the engine starts Do not allow the recoil star...

Страница 16: ...or Set Always connect the generator to the ground terminal to prevent electrical shock Add the watt ratings of all the loads that the generator set will be powering at the same time Make sure that tot...

Страница 17: ...own 3 Stop the generator set by pressing and holding the engine switch in the OFF position until the generator set stops 4 Rotate the fuel valve lever back to the OFF position When using LPG 1 Turn of...

Страница 18: ...he generator is running simply connect the power cords of 120 volt AC powered tools and equipment into the 120 volt AC dual outlets NOTE THE GENERATOR FEATURES AN AC NON FUSE CIRCUIT BREAKER TO PROTEC...

Страница 19: ...POSITIVE LEAD OF THE POWER CORD TO THE POSITIVE TERMINAL ON THE GENERATOR AND CONNECT THE NEGATIVE LEAD OF THE POWER CORD TO THE NEGATIVE TERMINAL ON THE GENERATOR 3 If using only a 12V volt DC tool o...

Страница 20: ...the insulator is cracked or chipped Clean the spark plug with a wire brush if it is to be reused 4 Measure the plug gap with a feeler gauge 5 Check that the spark plug washer is in good condition 7 Af...

Страница 21: ...nician before further use Do not use damaged equipment Before each use make sure the engine s oil and gas levels are adequate If necessary fill the crankcase until the oil level is even with the oil f...

Страница 22: ...ISTING EQUIPMENT WHEN MOVING IT TO THE INSTALLATION LOCATION ALWAYS CONNECT HOIST LINES TO THE FRAME OF THE GENERATOR General Location Make sure to locate and install the generator outdoors where cool...

Страница 23: ...ame to the concrete slab using 3 8 diameter expansion anchor bolts not supplied Grounding NOTE IT IS RECOMMENDED THAT ONLY A TRAINED AND LICENSED ELECTRICIAN PERFORM THIS PROCEDURE Connect a 6 AWG gro...

Страница 24: ...an the fuel sediment cup outlets Is the AC circuit breaker ON Turn the AC circuit breaker ON Check the electrical appliance or equipment for any defects Replace the electrical appliance or equipment T...

Страница 25: ...el DHLG225 Type 4 Strokes Air Cooling Single Cylinder OHV Horizontal Shaft Displacement cc 224 Ignition Mode Transistorized Magneto Starting Mode Recoil Start Fuel Tank Capacity L Gal 15 4 0 Oil Capac...

Страница 26: ...Wiring Diagra 26 03 017 1...

Отзывы: