Operation
14
Connecting to LPG Fuel Source
1.Locate the LPG converter on the f
ront
of the generator
.
2.Attach small end of the Gas Hose to the LPG converter.
3.Connect gas hose to propane fuel source. Do not turn on
propane source prior to following the steps outlined.
Starting the Generator Set
Ground Terminal
Before using generator, a ground wire must be connected to the ground terminal. The Ground
terminal is located on the Front Panel. Before using the ground terminal consult a qualified
electrician.
Ground Terminal Symbol:
The 5250Watt dual fuel generator can be started using the following method. Recoil Start
IF USING PROPANE FUEL SOURCE
1.Connect the gas pipe to the intake nozzle of regulator;
2. Open the valve of LPG bottle;
3.Turn the fuel selector to “LPG” position;
4. Push the engine switch to “ON” position;
5. Close the choke.
6.Continue to desired start-up method.
IF USING PROPANE FUEL SOURCE
1.The battery must be properly connected to the generator and check the battery voltage is
normal.
2.Turn on fuel valve.
3.Close the choke.
4. Push the engine switch to “ON” position
5. Turn the fuel selector to “GAS” position.
6.Continue to desired start-up method.
Содержание 5250DF
Страница 26: ...Wiring Diagra 26 03 017 1...