QP Series
Quincy Compressor
2022201802, July 2014
33
3501 Wismann Lane, Quincy Ill. - 62305-3116
PILOT VALVE ADJUSTMENTS
All adjustments made to the pilot valve must be performed by a qualified technician. The adjustments must
be made while the unit is operating, therefore, extreme caution must be taken while working on the unit.
Observe all necessary precautions. Always use a back-up wrench and make all differential and unload pres-
sure adjustments in very small increments (1/8 turn).
WARNING !
The pressure switch and / or pilot valve are set at the factory for maximum efficiency. Adjustments to either com
-
ponent must be performed by a qualified technician. Exceeding the factory recommended maximum pressure
will void the warranty and may cause personal injury.
*
Setting Unload Pressure
*
Step 1.
Flip the toggle to
the “RUN” position
as shown, or turn
the knurled knob (if
so equipped) coun-
terclockwise until it
stops.
Step 2.
Loosen locknut (coun-
terclockwise).
* Sta-
bilize with back-
up wrench!
Step 3.
Turn clockwise to increase unload pres-
sure, turn counterclockwise to decrease
unload pressure. Hold position with
wrench and proceed to Step 4.
Step 4.
Tighten locknut (clockwise) with wrench.
* Stabilize with back-up wrench!
Setting Differential Pressure
Step 5.
Loosen locknut (counterclock-
wise).
* Stabilize with back-up
wrench!
Step 6.
Turn clockwise to increase
the differential pressure and
counterclockwise to decrease
the differential pressure. Hold
position with wrench and pro-
ceed to Step 7.
Step 7.
Tighten locknut (clockwise)
with wrench.
* Stabilize with
back-up wrench!
“MANUAL
UNLOAD”
position
(Ref.)
Содержание QP Series
Страница 2: ......