QP Series
Quincy Compressor
2022201802, July 2014
29
3501 Wismann Lane, Quincy Ill. - 62305-3116
Lubrication
QP Series basic compressors and units are normally shipped from the
factory with break-in lubricant in the crankcase
.
Before starting your
compressor, check the lubricant level in the crankcase. The lubricant level of
QT-5, QP-5, QP-7.5 and QP-
10 compressors must be kept
at the top of the sightglass.
The lubricant level of QP-15
compressors must register be-
tween the high and low marks
on the dipstick.
Replace the
break-in lubricant after
100 hours of operation.
In
order to qualify for the Ster-
ling Blue 7 year Warranty,
Quin-Cip-D must be used in the QP Pro and Max packages. The Sterling Blue
100 Hour Kit is shipped with QP Pro and Max packages.
Quin-Cip and Quin-Cip-D
lubricants have proven under extensive testing
to min imize friction and wear, limit lubricant carryover, and reduce carbon
and varnish deposits. They will support the performance characteristics and
life designed into all Quincy compressors and are highly rec ommended. Refer
to the charts below to determine the correct amount of lubricant and viscosity
to use for your model and applica tion.
Approximate Crankcase Lubricant Capacities
Basic Compressor Model
Lubricant Capacity
QP-5 & QP-7.5
1 qt. & 26 oz. (1.72 lit.)
QP-10 2
qts. & 22 oz. (2.54 lit.)
QP-15
3 qts. & 30 oz. (3.73 lit.)
Lubricant Specifications
Quin-Cip
Ambient Temperature
SAE Viscosity
ISO Viscosity
0-32° F
SAE 10W
ISO 32
32-80°F
SAE 20W
ISO 68
60-104°F
SAE 30
ISO 100
Quin-Cip-D
Ambient Temperature
SAE Viscosity
ISO Viscosity
15-104°F
SAE 30
ISO 100
The lubricant selected must have a pour point at least15°F lower
than the minimum expected ambient temperature .
CAUTION !
Avg. # of Hrs.
Compressor
Operates Daily
# of Days of Operaton to
Reach:
50 Hrs.
100 Hrs.
4
13 days
25 days
6
9 days
17 days
8
6 days
13 days
10
5 days
10 days
Содержание QP Series