Section VIII - Technical data
Quincy Compressor
39
QOF 5
QOF 5
QOF 7.5
QOF 7.5
Frequency
Voltage
Overload
relay
Maximum
fuse
Overload
relay
Maximum
fuse
IEC
50 Hz
200 V 3~
17.3 A
50A
25.7A
50 A
50 Hz
230 V 3~
15.0 A
40 A
22.3 A
40 A
50 Hz
400 V 3~
8.7 A
16 A
12.8 A
25 A
50 Hz
400 V + N 3~ 8.7 A
16 A
12.8 A
25 A
UL/CUL
60 Hz
200 V 3~
16.6 A
25/25/30 A*
25.2 A
40/40/45 A*
60 Hz
208 V
--
--
24.3 A
40/40/45 A*
60 Hz
230 V 3~
15.2 A
25/25/30 A*
24.0 A
40/40/45 A*
60 Hz
460 V 3~
7.6 A
10/10/15 A*
12.0 A
20/20/20 A*
*: Maximum fuses according HRCII-C, according Class K5 for units without refrigerant
dryer and according Class K5 for units with refrigerant dryer respectively.
Temperature protection and safety valve settings
Temperature shut-down switch settings
Compressor element outlet temperature
Opens at
Reference
QOF 2 (8 bar / 116 psi)
70 °C (158 °F)
TDS1
QOF 2 (10 bar / 145 psi)
80° C (176 °F)
TSD1
QOF 3 (8 bar and 10 bar / 116 and 145 psi)
70 °C (158 °F)
TSD1
QOF 5 (8 bar and 10 bar / 116 and 145 psi)
70 °C (158 °F)
TSD1
QOF 7.5 (8 bar and 10 bar / 116 and 145 psi)
200 °C (392 °F)
TSD2
Safety valve
Pressure version
Set pressure
Unit
Reference
8 bar compressors
8.8
bar(e)
SV
116 psi compressors
135
psi(g)
SV
10 bar compressors
11
bar(e)
SV
145 psi compressors
160
psi(g)
SV