Section VI - Adjustments and servicing procedures
28
Quincy Compressor
2. Depressurize the compressor.
3. Remove the safety valve. See section Introduction for the location of the safety
valve (SV).
4. Test the safety valve on a separate compressed air circuit by gradually increasing
the pressure. If the safety valve does not open at the specified pressure, it must
be replaced. See section Temperature protection and safety valve settings for the
opening pressure of the safety valve.
WARNING!
No adjustments are allowed.
Never run the compressor without a safety valve.
Belt replacement
Procedure
NOTICE!
If more than one belt is used, the belts must be replaced as a set, even if only one
of them seems worn.
Use genuine spare parts belts only. The number of the belt set is mentioned in the
Parts list.
1. Remove the service panel (S).
2. Loosen screw (A).