![Quincy Compressor QOF 2 Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/quincy-compressor/qof-2/qof-2_instruction-manual_3802442044.webp)
Section VIII - Technical data
40
Quincy Compressor
Reference conditions and limitations
Reference conditions
Air inlet pressure (absolute)
bar
1
Air inlet pressure (absolute)
psi
14.5
Air inlet temperature
˚C
20
Air inlet temperature
˚F
68
Relative humidity
%
0
Working pressure
See section Compressor data.
Limits
Maximum working pressure
See section Compressor data.
Maximum air inlet temperature
˚C
40
Maximum air inlet temperature
˚F
104
Minimum ambient temperature
˚C
0
Minimum ambient temperature
˚F
32
Compressor data
NOTICE!
All data specified below apply under reference conditions, see section Reference
conditions and limitations.
Compressor type
QOF 2
QOF 2
QOF 3
QOF 3
8 bar
116 psi
10 bar
145 psi
8 bar
116 psi
10 bar
145 psi
Maximum working pressure (Pack)
bar(e)
8
10
8
10
Maximum working pressure (Pack)
psi(g)
116
145
116
145
Maximum working pressure (Full-
Feature)
bar(e)
7.75
9.75
7.75
9.75
Maximum working pressure (Full-
Feature)
psi(g)
112
141
112
141
Reference working pressure
bar(e)
7
10
7
10
Reference working pressure
psi(g)
100
145
100
145
Air temperature at outlet valve
(QOF), approx.
˚C
25
25
25
25
Air temperature at outlet valve
(QOF), approx.
˚F
77
77
77
77
Air temperature at outlet valve
(QOF with dryer), approx.
˚C
20
20
20
20
Air temperature at outlet valve
(QOF with dryer), approx.
˚F
68
68
68
68
Motor shaft speed (50 Hz)
r/min
1445
1445
2885
2885
Motor shaft speed (60 Hz)
r/min
1740
1740
3520
3520