Instruction book
2012 2039 28
106
5.6 Taking out of operation
Procedure
Step
Action
-
Stop the compressor and close the air outlet valve.
-
Switch off the voltage and disconnect the compressor from the mains.
-
If available, open the condensate drain valve(s) (Dm).
-
Shut off and depressurise the part of the air net which is connected to the outlet valve. Disconnect
the compressor air outlet pipe from the air net.
-
Drain the oil.
-
Drain the condensate circuit and disconnect the condensate piping from the condensate net.