Assembly
Technical features
Filter medium:
Degree of filtration :
90% of the dust emitted is filtered.
Total nominal flow :
6 000 m3/h
Filter panel number :
2
Initial charge loss :
75 Pa
Dimensions
Width :
500 mm
Height :
500 mm
Thickness :
200 mm
This option may be fitted to a compressor already installed.
10.4 Rotation direction indicator - Phase controller
Description
The phase controller enables permanent and easier verification of the rotation direction of the machine by
means of a diode. This prevents any risk of physical damage by disabling the compressor start up in case of
phase reversal or if a phase is disconnected and indicates a machine fault.
Marking on the motor of the standard machine version identifies the motor fan rotation direction during the
start up phase. Work on the electric network or the machine may change the rotation direction and damage
the compressor which must be detected quickly.