Item
Action
Ventilation
For water-cooled dryer:
• The inlet grid(s) (1) and ventilation fan (2) (if provided) should be installed in such
a way that natural circulation of air is guaranteed.
• The minimum air temperature at the dryer cooling opening is 0 ˚C (32 ˚F),
maximum air temperature at the dryer cooling opening is 40 °C (104 °F).
Air
• Connect the compressed air lines to the marked inlet and outlet pipes of the dryer.
• Provide an air inlet valve and outlet valve.
• If a by-pass pipe and valve are installed, the dryer can be serviced while being by-
passed.
Drain pipes
• Each drain pipe must be individually connected to the waste pipe.
• Lay out the condensate drain pipes via a funnel towards the waste pipe to allow
visual inspection. The pipes must slope downwards. For draining of pure
condensate, install an oil/water separator; consult your customer centre.
• If the condensate drain pipes have been fitted outside the compressor room where
they may be exposed to freezing temperatures, they must be insulated.
Water cooling
For water-cooled dryer:
• Connect the water cooling pipes to the marked inlet and outlet connections.
• It is recommended to fit a manual shut-off valve and drain in the water inlet and
outlet (customer's installation).
Electrical
connection
• Check that the primary side connections of transformer (T1) correspond with the
supply voltage.
• See the section
Electric cable size and fuses
for the recommended fuses and
cable size of the supply cables.
• Check that the electrical installation corresponds to the local codes. The dryer
must be earthed and protected against short circuits by fuses of the inert type in all
phases.
• An isolating switch must be installed near the dryer.
• The unit is provided with a phase sequence relay. When the dryer does not start,
switch off the voltage and reverse two incoming electric lines.
• All pipes should be installed stress-free to the dryer unit.
• All pipes should be installed so that there is no obstruction accessing the unit through
the removable panels.
4.4
Electric cable size and fuses
Important
Local regulations remain applicable if they are stricter than the values proposed.
For 50 Hz dryers, the settings of the main fuses below are according to Directive
2014/35/EU (low-voltage directive) EN60204, 2014/30/EU electromagnetic compatibility.
The cable size is valid for cable PVC 70 ˚C (158 ˚F) at an ambient temperature of 40 ˚C
(104 ˚F).
For 60 Hz dryers, the settings of the main fuses below are according to CSA standards
C22.2 Nos. 0; 0.4; 0.5; 0.12; 14; 68 and UL508. The cable size is valid for cable 90 ˚C (194
˚F) at an ambient temperature of 40 ˚C (104 ˚F).
Instruction book
96
2920 1992 00
Содержание QED-1250
Страница 2: ......
Страница 6: ...8 2 AIR DRYER DATA 108 9 Pressure equipment directives 112 Instruction book 4 2920 1992 00 ...
Страница 15: ...Position of components Air cooled dryer Water cooled dryer Instruction book 2920 1992 00 13 ...
Страница 17: ...Connections Rear view of Air cooled dryer Instruction book 2920 1992 00 15 ...
Страница 31: ...Electrical diagram air cooled QED 1800 ES870 Instruction book 2920 1992 00 29 ...
Страница 32: ...Electrical diagram air cooled QED 2100 ES1010 Instruction book 30 2920 1992 00 ...
Страница 33: ...Electrical diagram water cooled QED 1250 ES610 and QED 1600 ES760 Instruction book 2920 1992 00 31 ...
Страница 34: ...Electrical diagram water cooled QED 1800 ES870 and QED 2100 ES1010 Instruction book 32 2920 1992 00 ...
Страница 36: ...Electric cubicle air cooled QED 2100 ES1010 380 V and 460 V Instruction book 34 2920 1992 00 ...
Страница 86: ...Dimension drawing air cooled QED 1600 ES760 Instruction book 84 2920 1992 00 ...
Страница 87: ...Dimension drawing air cooled QED 1800 ES870 Instruction book 2920 1992 00 85 ...
Страница 88: ...Dimension drawing air cooled QED 2100 ES1010 Instruction book 86 2920 1992 00 ...
Страница 89: ...Dimension drawing water cooled QED 1250 ES610 Instruction book 2920 1992 00 87 ...
Страница 90: ...Dimension drawing water cooled QED 1600 ES760 Instruction book 88 2920 1992 00 ...
Страница 91: ...Dimension drawing water cooled QED 1800 ES870 Instruction book 2920 1992 00 89 ...
Страница 94: ...4 2 Installation proposal Example Installation proposal air cooled dryer Instruction book 92 2920 1992 00 ...
Страница 95: ...Installation proposal water cooled dryer Instruction book 2920 1992 00 93 ...
Страница 115: ......
Страница 116: ...No 2920 1992 00 2021 05 ...