Motor Replacements

The electrical motor is to be used solely as a direct replacement for a motor of the same model in QC 

Manufacturing, Inc., QuietCool products. Using the motor in any other product could result in electrical shock and/

or fire, which may cause property damage, serious injury or even death. Any motor replacement should be installed 

by a qualified licensed electrician in accordance with local, state and national electrical codes and standards. Make 

sure that power to the unit has been completely turned OFF at the breaker before approaching or inspecting or 

installing the replacement motor.   If found that the motor failure was by improper installation QC will not be liable 

for any cost associated with the motor replacement.  For example, cost of motor and shipping costs to and from 

the customer.  Repairs and replacement parts supplied under this warranty are warranted only for the period listed 

in the below chart from the date of original retail purchase of the unit. 

Other Conditions

This warranty is the entire agreement between you and QC Manufacturing, Inc., and there are no other oral 

or written warranties, liabilities or obligations of QC Manufacturing except apart from those set forth herein. 

Pertinent state law shall control for what period of time subsequent to sale a consumer/homeowner may seek a 

remedy pursuant to the implied warranty of merchantability or fitness for a particular purpose. In no event shall 

QC Manufacturing, Inc. be liable for consequential or incidental damages of any kind, including any damage 

to the building, its contents or any persons therein, resulting from the breach of any warranty set forth herein, 

unless exclusion of these types of damages are specifically prohibited by state law. No field representative of QC 

Manufacturing, Inc. or any distributor or dealer is authorized to make any change or modifications to this warranty. 

Products

Model Numbers

Warranty

Trident Pro X Models

QC TRI PRO-1.5X, QC TRI PRO-2.5X, 

QC TRI PRO-3.3X, QC TRI PRO-4.8X, 

QC TRI PRO-5.5X, QC TRI PRO-6.0X, 

QC TRI PRO-7.0X

Fifteen (15) Year coverage applies to the 

QuietCool motor fan assembly. Which 

includes Motor and Fan Blade.

One (1) Year coverage for all other 

components including grilles, housings, damper 

boxes, ducts, controls and accessories furnished by 

QC Manufacturing, Inc.

Stealth Pro X Models

QC STL PRO-1.5X, QC STL PRO-2.5X, 

QC STL PRO-3.3X, QC STL PRO-4.8X, 

QC STL PRO-5.5X, QC STL PRO-6.0X, 

QC STL PRO-7.0X

Accessories

Model Numbers

Warranty

Controls

IT-RFHUB-01, IT-RFSWITCH-01, 

IT-30070, IT-30045, IT-35000

One (1) Year coverage applies to the models 

indicated.

How to Start the Warranty Process

To obtain service under this warranty, first contact your dealer where you purchased the equipment. If you are 

unable to find or reach your dealer, contact Customer Service at QC Manufacturing, Inc. by phone, email or visiting 

our website at 

https://quietcoolsystems.com/support/return-merchandise-authorization/

 to start the RMA process.   

An RMA (Return Merchandise Authorization) form is required for returns to the factory to ensure your return can 

be processed efficiently and quickly. There is no informal dispute settling mechanism available in the event of a 

controversy involving this warranty 

QC Manufacturing, Inc. Customer Service

26040 Ynez Rd.

Temecula, CA 92591

www.QuietCoolSystems.com

951-325-6340

Rev. 9/26/22

Содержание QC TRI PRO-1.5X

Страница 1: ...DO NOT THROW AWAY SERIAL NUMBER FOR FAN IS LOCATED ON THE BACK COVER OF THE OWNER S GUIDE LEAVE WITH HOMEOWNER OWNER S GUIDE TRIDENT PRO X WHOLE HOUSE FAN...

Страница 2: ...nts 7 GETTING STARTED IMPORTANT READ BEFORE INSTALL 8 3 INSTALLATION 10 3 1 Installing QuietCool 10 3 2 Installing Vertical Adapter 12 4 WIRING 13 4 1 Single Speed Wiring QC TRI PRO 1 5X 13 4 2 Two Sp...

Страница 3: ...o a loud vacuum cleaner running The QuietCool system uses a cutting edge patented design to get our sound levels down to a respectable level Our fans suspend in the attic and use an acoustical duct th...

Страница 4: ...arly evening is spent in the kitchen or family room area Assuming this to be true this is where you would want to start the cooling process Begin opening a few windows in the area you are going to be...

Страница 5: ...healthier If you have any trouble installing or operating your new QuietCool whole house fan or for more tips on running the QuietCool please visit our website www QuietCoolSystems com or call us at...

Страница 6: ...from potential injury or fan obstruction F HIGH PERFORMANCE ACOUSTICAL DUCTING Noise dampening technology with insulated ducting that is used to separate the Steel Housing from the living space G AIR...

Страница 7: ...ould with 1 750 attic venting But don t worry the system will still operate if there is not enough venting Insufficient venting is a very simple problem to fix Roofing contractors can add extra ventin...

Страница 8: ...Care should be taken to avoid backdrafting combustion appliances that are installed in the conditioned space Whole house fans are capable of pulling large quantities of air from the home particularly...

Страница 9: ...ST your QuietCool unit before installation using the included power cord If the fan does not work call us immediately SPECIAL INSTRUCTIONS TO CONTRACTORS 1 DO NOT take the Owner s Guide with you after...

Страница 10: ...cut out the hole in the ceiling 4 Open and unpack your QuietCool fan TIP If your attic is very tight you may want to wire your QuietCool motor housing before bringing it into the attic Please follow t...

Страница 11: ...s in place when you are screwing in the grille If you do not fasten the damper box to the drywall the damper box will not stay in place when attempting to screw in the grille 9 Remove ceiling grille a...

Страница 12: ...side of the vertical adapter Place the vertical adapter with the T side up onto the damper box with the side that has only two flanges flush on the damper box 2 If you have studs spaced at 16 on cent...

Страница 13: ...m wiring a dedicated circuit may be required NOTE Your fan came pre wired to a power cord for testing purposes before installation If you would like to hard wire the fan or it is required by your loca...

Страница 14: ...rom the power cord Remove the power cord and strain relief connector 8 Re attach the ground screw and wire to the handy box Cut your green ground wire in half and strip both sides see Figure 4 1B 9 In...

Страница 15: ...e green ground wire on the timer 3 Using the included wire nuts tie the black wire from the 2 wire power source to the black wire on the timer Tie the white neutral wire from the 2 wire power source t...

Страница 16: ...d Remove the power cord and strain relief connector 8 Re attach the ground screw and wire to the handy box Cut your green ground wire in half and strip both sides see Figure D 9 Install the included r...

Страница 17: ...or multi speed QuietCool fans on one single speed TWO SPEED CONTROLS TIMER HIGH LOW OFF SWITCH To control a multi speed QuietCool fan we recommend the 8 Hour Countdown Timer and a HIGH LOW OFF Switch...

Страница 18: ...installed or by movement distortion cracking or settling of walls or the foundation of the building QC Manufacturing Inc reserves the right to discontinue or modify any of its products including witho...

Страница 19: ...ny kind including any damage to the building its contents or any persons therein resulting from the breach of any warranty set forth herein unless exclusion of these types of damages are specifically...

Страница 20: ...FAN SERIAL NUMBER INFORMATION RETAIN FOR YOUR RECORDS SERIAL NUMBER IS REQUIRED FOR WARRANTY PURPOSES 1 888 QUIETCOOL WWW QUIETCOOLSYSTEMS COM Rev 9 26 22...

Отзывы: