background image

QUIETCOOLSYSTEMS.COM

9

WELCOME

INST

ALLA

TION

WIRING

OPERA

TION

W

ARRANTY

INCLUDED IN THE BOX

 

- QuietCool Whole House Fan    - QuietCool Damper Box    - QuietCool Duct    - Ceiling Grille   

- Window locks (2)     - Accessory Bag containing needed hardware     - Cut-out Template     - Controls

SPECIAL INSTRUCTIONS

1.   CHECK the box when opening for the first time; loose parts may shift during shipping. Check
  box contents against the section “Included in the Box” before proceeding with installation. Do 
  NOT throw away the shipping box until completely satisfied with the product. Note: Included 
  controls will be located at the bottom of the box.
2.   BEFORE CUTTING into ceiling drywall, “measure twice, cut once.” This ensures that you don’t 
  make mistakes in either selecting the wrong location for the intake grille, or cutting the wrong 
  size hole.  
3.   READ wiring instructions BEFORE attempting to wire the product. Product warranty does NOT 
  cover defective motors resulting from wiring errors.
4.   DO NOT use any QuietCool ducted whole house fan in a home with all closed windows.
5.   TEST your QuietCool unit before installation using the included power cord. If the fan does not
  work, call us immediately.

SPECIAL INSTRUCTIONS TO CONTRACTORS

1.   DO NOT take the Owner’s Guide with you after the installation. This Owner’s Guide has the serial 
  number and warranty information of the homeowner’s product.
2.   DEMONSTRATE the use of the product to the customer before leaving the home, INCLUDING; 
  explain the use of the timer, switch, and/or smart application as applicable. 
3.   PROVIDE the customer with a completed invoice that clearly shows your company name, product
  model # and product serial number, date of sale and installation, and price paid.  The manufacturer is 
  not liable for warranty claims where proof of purchase cannot be verified.

SPECIAL INSTRUCTIONS TO DO-IT-YOURSELFERS

1.   DO NOT attempt to install any QuietCool cooling and ventilation system yourself if you lack 
  sufficient skill and experience to do so.
2.   WATCH the installation videos on the manufacturer website by visiting 
  www.QuietCoolSystems.com/support or by scanning any QR code found in this guide that appears    
  next to any instructional step.

TOOLS YOU WILL NEED

 

- Cordless Drill with Nut Driver and Philips Bit    - Drywall Saw    - Measuring Tape    - Carpenter Pencil

Содержание QC TRI PRO-1.5X

Страница 1: ...DO NOT THROW AWAY SERIAL NUMBER FOR FAN IS LOCATED ON THE BACK COVER OF THE OWNER S GUIDE LEAVE WITH HOMEOWNER OWNER S GUIDE TRIDENT PRO X WHOLE HOUSE FAN...

Страница 2: ...nts 7 GETTING STARTED IMPORTANT READ BEFORE INSTALL 8 3 INSTALLATION 10 3 1 Installing QuietCool 10 3 2 Installing Vertical Adapter 12 4 WIRING 13 4 1 Single Speed Wiring QC TRI PRO 1 5X 13 4 2 Two Sp...

Страница 3: ...o a loud vacuum cleaner running The QuietCool system uses a cutting edge patented design to get our sound levels down to a respectable level Our fans suspend in the attic and use an acoustical duct th...

Страница 4: ...arly evening is spent in the kitchen or family room area Assuming this to be true this is where you would want to start the cooling process Begin opening a few windows in the area you are going to be...

Страница 5: ...healthier If you have any trouble installing or operating your new QuietCool whole house fan or for more tips on running the QuietCool please visit our website www QuietCoolSystems com or call us at...

Страница 6: ...from potential injury or fan obstruction F HIGH PERFORMANCE ACOUSTICAL DUCTING Noise dampening technology with insulated ducting that is used to separate the Steel Housing from the living space G AIR...

Страница 7: ...ould with 1 750 attic venting But don t worry the system will still operate if there is not enough venting Insufficient venting is a very simple problem to fix Roofing contractors can add extra ventin...

Страница 8: ...Care should be taken to avoid backdrafting combustion appliances that are installed in the conditioned space Whole house fans are capable of pulling large quantities of air from the home particularly...

Страница 9: ...ST your QuietCool unit before installation using the included power cord If the fan does not work call us immediately SPECIAL INSTRUCTIONS TO CONTRACTORS 1 DO NOT take the Owner s Guide with you after...

Страница 10: ...cut out the hole in the ceiling 4 Open and unpack your QuietCool fan TIP If your attic is very tight you may want to wire your QuietCool motor housing before bringing it into the attic Please follow t...

Страница 11: ...s in place when you are screwing in the grille If you do not fasten the damper box to the drywall the damper box will not stay in place when attempting to screw in the grille 9 Remove ceiling grille a...

Страница 12: ...side of the vertical adapter Place the vertical adapter with the T side up onto the damper box with the side that has only two flanges flush on the damper box 2 If you have studs spaced at 16 on cent...

Страница 13: ...m wiring a dedicated circuit may be required NOTE Your fan came pre wired to a power cord for testing purposes before installation If you would like to hard wire the fan or it is required by your loca...

Страница 14: ...rom the power cord Remove the power cord and strain relief connector 8 Re attach the ground screw and wire to the handy box Cut your green ground wire in half and strip both sides see Figure 4 1B 9 In...

Страница 15: ...e green ground wire on the timer 3 Using the included wire nuts tie the black wire from the 2 wire power source to the black wire on the timer Tie the white neutral wire from the 2 wire power source t...

Страница 16: ...d Remove the power cord and strain relief connector 8 Re attach the ground screw and wire to the handy box Cut your green ground wire in half and strip both sides see Figure D 9 Install the included r...

Страница 17: ...or multi speed QuietCool fans on one single speed TWO SPEED CONTROLS TIMER HIGH LOW OFF SWITCH To control a multi speed QuietCool fan we recommend the 8 Hour Countdown Timer and a HIGH LOW OFF Switch...

Страница 18: ...installed or by movement distortion cracking or settling of walls or the foundation of the building QC Manufacturing Inc reserves the right to discontinue or modify any of its products including witho...

Страница 19: ...ny kind including any damage to the building its contents or any persons therein resulting from the breach of any warranty set forth herein unless exclusion of these types of damages are specifically...

Страница 20: ...FAN SERIAL NUMBER INFORMATION RETAIN FOR YOUR RECORDS SERIAL NUMBER IS REQUIRED FOR WARRANTY PURPOSES 1 888 QUIETCOOL WWW QUIETCOOLSYSTEMS COM Rev 9 26 22...

Отзывы: