background image

6

QUIETCOOLSYSTEMS.COM

VERY IMPORTANT:

 Make sure the fan blade spins freely. 

This is very important to system operation

NOTE:

 Local building codes and standards must be 

adhered to in the installation of this unit.

AVOID BACK DRAFTS:

 

Care should be taken to avoid 

back drafting combustion appliances that are installed 
in the conditioned space. It is strongly recommended 
that combustion appliances 

NOT

 be installed in such a manner that they use room air for 

combustion. Whole house fans are capable of pulling large quantities of air, from the home 
and particularly if not enough windows are open. This could easily back draft gas appliances 
located inside your home.

3. WIRING

NOTE:

 Wiring Diagrams are for examples only and wiring should be done by an experienced 

electrician! 

3.1.  Single Speed Wiring

For wiring of the ES-1500, ES-2250, & ES-3100 with one speed

3.2.  Two Speed Wiring

For wiring of the ES-4700 with two speeds.

3.3.  Two Speed Wiring (ES-6400)

For wiring of the ES-6400 double motorhead whole house fan with two 
speeds.

NOTE:

 The QuietCool whole house fans can be used with the included power cord with a 

plug outlet, but will only operate on high speed. The system will also work with a wireless 
system using the power cord.

Содержание ES-1500

Страница 1: ...1 QUIETCOOLSYSTEMS COM SEE HEAR FEEL THE QUIETCOOL DIFFERENCE THE NATURAL CHOICE FOR ENERGY SAVINGS OWNER S GUIDE ENERGY SAVER CLASSIC LINE...

Страница 2: ...n 6 Heat The QuietCool system should be situated away from heat sources 7 Damage Requiring Service Only qualified service personnel should service the QuietCool system The user should not attempt to s...

Страница 3: ...r running In contrast our QuietCool whole house fans average at just around 45 dB that s equivalent to quiet conversation The QuietCool system uses a cutting edge patented design to get our sound leve...

Страница 4: ...RTANT 1 SQUARE FOOT OF NET FREE VENTING PER 750 CFM REQUIRED VENTILATION 1 SQ FT FOR EACH 750 CFM Vent Type Model Type Average Size Venting Sq Ft Gable vent 12 x 19 5 1 20 Dormer Vent 14 x 8 0 70 Eave...

Страница 5: ...mark the exact location for each fan Take the cardboard cut out template and a small screwdriver with you Make sure the template fits between the framing The rough opening size varies depending on wh...

Страница 6: ...place mark its outline with a pencil NOTE Repeat these steps at each location 4 Using a drywall saw or similar device cut out the hole in the ceiling NOTE Repeat these steps at each location 5 Open a...

Страница 7: ...the drywall or the joist in the attic While holding it in place install a 1 3 8 drywall screw through the drywall into the flange of the damper box on each side to temporarily hold the box in place Re...

Страница 8: ...e quantities of air from the home and particularly if not enough windows are open This could easily back draft gas appliances located inside your home 3 WIRING NOTE Wiring Diagrams are for examples on...

Страница 9: ...opening up the handy box Take off the wire nuts within the handy box Unscrew the green ground wire Detach the green ground wire from the power cord Remove the power cord Re attach the ground screw and...

Страница 10: ...wire to the top gold screw on the right of the switch Then attach the black wire to the bottom gold screw see Figure 3 2A 3 With a piece of bare copper wire attach it to the green ground screw on the...

Страница 11: ...Speed Whole House Fans Tie All Ground Bare Copper Wires Together 14 2 Wire 8 HOUR 4 HOUR 2 HOUR 1 HOUR HOLD Black High Speed High OFF Low 14 2 Wire Figure 3 2A Power Timer Tie All Ground Bare Copper...

Страница 12: ...x from your power source tie the black wire to the black wire on the timer with a wire nut 5 Take a piece of bare copper wire and attach it to the green ground screw on the switch Using a wire nut tie...

Страница 13: ...Ground Bare Copper Wires Together 14 2 Wire 8 HOUR 4 HOUR 2 HOUR 1 HOUR HOLD 14 2 Wire 14 2 Wire Power Source Black Tied Together with Black Red Switch Leg Off On On Off Two Speed Wiring Tie Common Wi...

Страница 14: ...windows will lessen the cooling breeze you feel The breeze will flow through your home and make its way to each QuietCool you have in operation As it gets later in the evening and even cooler outside...

Страница 15: ...or the labor charge to un install any components 3 Product failure or damage due to faulty installation abuse misuse unauthorized alteration to factory specs lack of maintenance or transportation dam...

Страница 16: ...14 1 888 QUIETCOOL 43352 Business Park Drive Temecula CA 92590 PH 951 325 6340 QUIETCOOLSYSTEMS COM QuietCool is Proudly Designed and Built in California...