34
10. Error Indication
11. Resistance values for remote sensor
Recycling
CONFIGURATION
Display- and powermodule do not fit
use only suitable parts
switch off and on power supply
EXT SENSOR
1. Error of remote sensor
replace sensor
2. Over- or under run of valid display range
COMMUNICATION
Communication between display- and power unit fails
unplug and re-plug display unit
switch off and on power supply
Temperature
Resistance
Temperature
Resistance
10 °C
66,8 kΩ
30 °C
26,3 kΩ
20 °C
41,3 kΩ
40 °C
17,0 kΩ
25 °C
33,0 kΩ
50 °C
11,3 kΩ
In case of errors, «Err» is blinking. The following errors can be displayed:
On all these errors, heating will be activated with 30% of time
This product should not be disposed of with household waste.
Please recycle the products where facilities for electronic waste exist. Check
with your local authorities for recycling advice.