29
EN
RDS 1562 - IT EN - REV001A
TROUBLESHOOTING
WARNING MESSAGES
STATUS MESSAGES
MESSAGE
DESCRIPTION
Batt M lo
The battery’s or battery bank’s voltage, measured on the MASTER output terminal, is lower than 11 Vdc
(mod. SBC 600 NRG+ FR, SBC 700 NRG+ FR, SBC 1100 NRG+ FR, SBC 1200 NRG+ FR) or 22 Vdc (mod. SBC 750 NRG+ FR,
SBC 950 NRG+ FR, SBC 1450 NRG+ HR, SBC 1950 NRG+ HR, SBC 2450 NRG+ HR). As soon as the voltage goes back to a higher/
equal value to 11 Vdc, the notification disappears (mod. SBC 600 NRG+ FR, SBC 700 NRG+ FR, SBC 1100 NRG+ FR, SBC 1200
NRG+ FR) o 22 Vdc (mod. SBC 750 NRG+ FR, SBC 950 NRG+ FR, SBC 1450 NRG+ HR, SBC 1950 NRG+ HR, SBC 2450 NRG+ HR).
Batt M hi
The battery’s or battery bank’s voltage, measured on the MASTER output terminal, is higher than 14,8 Vdc
(mod. SBC 600 NRG+ FR, SBC 700 NRG+ FR, SBC 1100 NRG+ FR, SBC 1200 NRG+ FR) or 29,6 Vdc (mod. SBC 750 NRG+ FR,
SBC 950 NRG+ FR, SBC 1450 NRG+ HR, SBC 1950 NRG+ HR, SBC 2450 NRG+ HR). As soon as the voltage goes back to a lower/
equal value to 14,8 Vdc, the notification disappears (mod. SBC 600 NRG+ FR, SBC 700 NRG+ FR, SBC 1100 NRG+ FR, SBC 1200
NRG+ FR) o 29,6 Vdc (mod. SBC 750 NRG+ FR, SBC 950 NRG+ FR, SBC 1450 NRG+ HR, SBC 1950 NRG+ HR, SBC 2450 NRG+ HR).
Batt 1 lo
The battery’s or battery bank’s voltage, measured on the SLAVE1 output terminal, is lower than 11 Vdc
(mod. SBC 600 NRG+ FR, SBC 700 NRG+ FR, SBC 1100 NRG+ FR, SBC 1200 NRG+ FR) o 22 Vdc (mod. SBC 750 NRG+ FR,
SBC 950 NRG+ FR, SBC 1450 NRG+ HR, SBC 1950 NRG+ HR, SBC 2450 NRG+ HR). As soon as the voltage goes back to a higher/
equal value to 11 Vdc, the notification disappears (mod. SBC 600 NRG+ FR, SBC 700 NRG+ FR, SBC 1100 NRG+ FR, SBC 1200
NRG+ FR) o 22 Vdc (mod. SBC 750 NRG+ FR, SBC 950 NRG+ FR, SBC 1450 NRG+ HR, SBC 1950 NRG+ HR, SBC 2450 NRG+ HR).
Batt 1 hi
The battery’s or battery bank’s voltage, measured on the SLAVE1 output terminal, is higher than 14,8 Vdc
(mod. SBC 600 NRG+ FR, SBC 700 NRG+ FR, SBC 1100 NRG+ FR, SBC 1200 NRG+ FR) or 29,6 Vdc (mod. SBC 750 NRG+ FR,
SBC 950 NRG+ FR,SBC 1450 NRG+ HR, SBC 1950 NRG+ HR, SBC 2450 NRG+ HR). As soon as the voltage goes back to a lower/
equal value to 14,8 Vdc, the notification disappears (mod. SBC 600 NRG+ FR, SBC 700 NRG+ FR, SBC 1100 NRG+ FR, SBC 1200
NRG+ FR) or 29,6 Vdc (mod. SBC 750 NRG+ FR, SBC 950 NRG+ FR, SBC 1450 NRG+ HR, SBC 1950 NRG+ HR, SBC 2450 NRG+ HR).
Batt 2 lo
The battery’s or battery bank’s voltage, measured on the SLAVE2 output terminal, is lower than 11 Vdc
(mod. SBC 600 NRG+ FR, SBC 700 NRG+ FR, SBC 1100 NRG+ FR, SBC 1200 NRG+ FR) o 29,6 Vdc (mod. SBC 750 NRG+ FR,
SBC 950 NRG+ FR, SBC 1450 NRG+ HR, SBC 1950 NRG+ HR, SBC 2450 NRG+ HR). As soon as the voltage goes back to a higher/
equal value to 11 Vdc, the notification disappears (mod. SBC 600 NRG+ FR, SBC 700 NRG+ FR, SBC 1100 NRG+ FR, SBC 1200
NRG+ FR) o 22 Vdc (mod. SBC 750 NRG+ FR, SBC 950 NRG+ FR, SBC 1450 NRG+ HR, SBC 1950 NRG+ HR, SBC 2450 NRG+ HR).
Batt 2 hi
The battery’s or battery bank’s voltage, measured on the SLAVE2 output terminal, is higher than 14,8 Vdc
(mod. SBC 600 NRG+ FR, SBC 700 NRG+ FR, SBC 1100 NRG+ FR, SBC 1200 NRG+ FR) o 29,6 Vdc (mod. SBC 750 NRG+ FR,
SBC 950 NRG+ FR, SBC 1450 NRG+ HR, SBC 1950 NRG+ HR, SBC 2450 NRG+ HR). As soon as the voltage goes back to a lower/
equal value to 14,8 Vdc, the notification disappears (mod. SBC 600 NRG+ FR, SBC 700 NRG+ FR, SBC 1100 NRG+ FR, SBC 1200
NRG+ FR) o 29,6 Vdc (mod. SBC 750 NRG+ FR, SBC 950 NRG+ FR, SBC 1450 NRG+ HR, SBC 1950 NRG+ HR, SBC 2450 NRG+ HR).
MESSAGE
DESCRIPTION
BULK
The battery charger is in the BULK phase.
(See paragraph “OPERATION - Charging characteristics” in the NRG+ battery charger manual).
ABSORPTION
The battery charger is in the ABSORPTION phase.
(See paragraph “OPERATION - Charging characteristics” in the NRG+ battery charger manual)
FLOAT
The battery charger is in the FLOAT phase.
(See paragraph “OPERATION - Charging characteristics” in the NRG+ battery charger manual)
Derating
The battery charger performs a limitation on the maximum output current due to a thermal problem, due a fan which is
not working or due low AC voltage.
Monitor
The battery charger is in monitor mode (See “monitor mode”).
Limit power
The manual mode of the maximum output current reduction has been activated. (See “maximum output current”).
Silent mode
The silent mode for the cooling fans has been activated. (See “silent mode”).
Sharing on
The battery charger is carrying out the current sharing with 2 or 3 battery chargers connected in parallel.
Charge comp
The battery charger is carrying out the batteries’ charge compensation according to their temperature.
It is activated only if the KTBRJ temperature sensor (supplied) is connected to the battery charger or if the KTB4 interface
(not supplied) with the relevant sensors is connected to the system.
Содержание RDS 1562
Страница 2: ......
Страница 33: ...33 33 RDS 1562 IT EN REV001A NOTES...
Страница 34: ...NOTES...
Страница 35: ......