A possible CAN network is illustrated below:
SETTING UP THE INSTRUMENT
The instrument is set up using a dip-switch. To configure the unit, priority of the battery charger which the infor-
mation is shown for and CAN termination, refer to the table given below:
SWITCH 1
OFF
OFF
ON
SWITCH 2
OFF
ON
OFF
GROUP
A
GROUP
B
GROUP
C
FUNCTION
DESCRIPTION
SWITCH 6
Not used
ON
1 2
3 4 5 6
ON
1 2
3 4 5 6
ON
1 2
3 4 5 6
SWITCH 3
OFF
OFF
ON
SWITCH 4
OFF
ON
OFF
PRIORITY
1
PRIORITY
2
PRIORITY
3
FUNCTION
DESCRIPTION
ON
1 2
3 4
5 6
ON
1 2
3 4
5 6
ON
1 2
3 4
5 6
SWITCH 5
OFF
ON
CAN TERMINATOR DEACTIVATED
CAN TERMINATOR ACTIVATED
FUNCTION
DESCRIPTION
FACTORY SETTING:
ON
1 2 3 4
5
6
ON
1 2 3 4
5
6
GROUP
A
PRIORITY
1
CAN TERMINATION DEACTIVATED
RDS 1520
KTB4
RCM1620
RDS1540
RCM1620
RDS1520
GSM
INTERFACE
LCD
TERMINAL
GROUP A
GROUP B
GROUP U
SBC 1950
ADVANCED
PLUS
(Priority 2)
SBC 1950
ADVANCED
PLUS
(Priority 3)
SBC 1950
ADVANCED
PLUS
(Priority 1)
SBC 1100
ADVANCED
PLUS
UNITS IN PARALLEL
CAN NETWORK
RDS1540
OPERATING