6 - Cautions & Use

6.2 - Troubleshooting

If the windlass stops and the hydraulic magnetic (or thermal magnetic*) switch has not tripped, wait a few seconds and try 

again (avoid keeping the button pressed).

If the hydraulic magnetic switch, has tripped, reset it and wait a few minutes before weighing anchor once again.

If, after a number of attempts, the windlass is still blocked, we suggest to move the boat to release the anchor.

7 - Maintenance

WARNING:

 make sure the electrical power to the motor is switched off when working manually on the windlass. 

Carefully remove the chain from the gypsy or the rope from the drum.

Quick® windlasses are made of materials resistant to the marine environment: it is essential, in any case, to periodically 

remove salt deposits that form on the external surfaces to avoid corrosion and consequently damage to the device.

Thoroughly wash the surfaces and parts where salt can deposit with fresh water.

Once a year, disassemble the gypsy and the drum according to the following sequence:

• Use the handle (1) to remove the gypsy cover (2)

• Remove the top clutch cone (3)

• Open the chain guide cover (7)

• Undo the retaining screws (5)

• Remove the gypsy (4)

• Remove the clutch washer (6)

Clean all the parts removed to avoid corrosion, and grease (with marine grease) the shaft thread and the gypsy where the 

clutch cones rest.

Remove any oxide deposits from the terminals of the electric motor and the reversing contactor unit; grease them.

If required, windlass must be disassembled by qualified personnel. 

Make sure that the gearmotor is cold before disassembling it.

The disposal must be carried out according to the regulations of the place where the work is carried out.

8 - Product disposal

As with installation, at the end of this product life, dismantling must be carried out by qualified personnel.

This product is made up of various materials, some can be recycled and others must be suitably disposed of; enquire about the 

recycling or disposal systems provided for by local regulations for this product category.

Some parts of the product may contain pollutants or hazardous substances that, if dispersed, may be harmful to the 

environment and human health.

As indicated by the symbol on the side, it is forbidden to dispose of this product as domestic waste. 

Separate the products for disposal in accordance with the regulations in force in your area or return the product 

to the seller when purchasing a new equivalent product. Local regulations may impose severe penalties for the 

improper disposal of this product.

Содержание DP2 L 770

Страница 1: ...DP2 L 770 REV 000A VERTICAL WINDLASSES EN INSTALLATION AND USER S MANUAL Other languages available by scanning the QR code on the back of this manual or on the label on the product...

Страница 2: ......

Страница 3: ...allation 6 2 2 Recommended Quick accessories not included 6 3 Introduction 6 3 0 Important notes 6 3 1 Precautions 7 3 2 Precautions for the installer 7 4 Installation 7 4 0 Installation requirements...

Страница 4: ......

Страница 5: ...ecific circuit breaker for direct current DC and delayed circuit breaker thermal magnetic or hydraulic magnetic 5 On request studs can be supplied for greater deck thicknesses 6 Only on request BARBOT...

Страница 6: ...push button panel HRC 1002 Foot switch 900 Hydraulic magnetic circuit breaker WCB Anchor chain counter CHC 1102M CHC 1202M Control system via RRC radio R02 P02 H02 3 Introduction BEFORE USING THE PROD...

Страница 7: ...fixed points such as chain stopper or bollard To prevent accidental releases the anchor must be secured The windlass must not be used as sole securing device Isolate the windlass from the electrical...

Страница 8: ...o the fixing studs Connect the supply cables from the windlass to the reversing contactor unit STUD B DECK LEVEL Ensure that the upper and lower surfaces of the deck are as parallel as possible If thi...

Страница 9: ...HRC 1002 MOTOR BATTERY HYDRAULIC MAGNETIC CIRCUIT BREAKER see table on page 5 REVERSING CONTACTOR UNIT mod T6411 12 12V C A2 FOOT SWITCHES MOD 900U AND 900D BLACK BROWN BLUE BROWN BLACK BLUE A1 FUSE 4...

Страница 10: ...e The clutch B provides a link between the gypsy and the main shaft A The clutch can be released disengagement by using handle C which when inserted into bush D of the drum or into the gypsy cover 6 m...

Страница 11: ...taining screws 5 Remove the gypsy 4 Remove the clutch washer 6 Clean all the parts removed to avoid corrosion and grease with marine grease the shaft thread and the gypsy where the clutch cones rest R...

Страница 12: ...TE GYPSY DP2 5 SCREW 6 LOWER WASHER 7 CHAIN GUIDE COVER DP2 8 STUD 9 WASHER 10 SERRATED WASHER 11 NUT 12 OIL SEAL 13 BEARING 14 EXTERNAL SNAP RING 15 SHAFT DP2L 16 KEY 17 SHAFT WHEEL 18 EXTERNAL SNAP...

Страница 13: ...oduce changes to the equipment and the contents of this manual without prior notice In case of discordance or errors in translation between the translated version and the original text in the Italian...

Страница 14: ...QUICK S p A Via Piangipane 120 A 48124 Piangipane RAVENNA ITALY Tel 39 0544 415061 Fax 39 0544 415047 www quickitaly com quick quickitaly com Product serial number DP2 L 770 REV 000A...

Отзывы: