background image

EN

DP2 L 770

Max 10°

2A

1A

3A

4A

QUICK 

DP2_L 770

 INSTALLATION AND USER’S MANUAL - REV000A

7

3 - Introduction

3.1 - Precautions

Quick

®

 windlasses are designed and manufactured to weigh the anchor.

• Do not use these products for any other type of operation.

• Quick

®

 shall not be held liable for direct or indirect damage caused by improper use of the product.

• The windlass is not designed to support loads generated in particular weather conditions (storm).

• Operate the product from a position where it is possible to supervise the work area.

• Always deactivate the windlass when not being used.

• Make sure that there are no bathers nearby before dropping the anchor.

• The splice between the rope and the chain must be tightly woven for the rope to slide easily into the gypsy shape. 

For any problem or request, feel free to contact Quick® Technical Service.

• For improved safety, we recommend installing at least two controls to operate the windlass in case one is 

damaged.

• We recommend the use of Quick

®

 switch as motor safety device.

• Secure the chain with a retainer before sailing off.

• The reversing contactor box must be installed in a position protected from any water entry.

• 

After completing the anchorage, secure the chain to fixed points such as chain stopper or bollard.

• To prevent accidental releases, the anchor must be secured. The windlass must not be used as sole securing 

device.

• 

Isolate the windlass from the electrical system during navigation and secure the rope to a fixed point of the boat.

• This equipment is not intended for use by people (including children) with reduced physical, sensory or mental 

capabilities. 

3.2- Precautions for the installer

CARRY OUT THE INSTALLATION IN GOOD LIGHTING CONDITIONS.

It is advisable to wear suitable clothing and personal protective equipment (PPE). 

The product is not suitable for installation in potentially explosive environments and/or atmospheres.

Installation and subsequent inspection or repair work must only be carried out by qualified personnel.

CARRY OUT INSTALLATION/MAINTENANCE WORK MAKING SURE THAT THE PRODUCT IS DISCONNECTED 

FROM THE ELECTRICAL SYSTEM.

Quick

®

 accepts no responsibility for inadequate connection of users to the electrical system and inadequate safety 

of the electrical system.

4 - Installation

4.0 - Installation requirements

A ROLLER ALIGNMENT

The windlass must be positioned by aligning the gypsy with the bow roller (fig. 

1A 

2A

).

Precise alignment of the windlass is essential for the correct operation of the product.

A positive chain tilt of up to 10° is allowed (fig. 

2A

).

An excessive negative tilt of the chain could interfere with the windlass base (fig. 

3A

 / 

4A

).

Содержание DP2 L 770

Страница 1: ...DP2 L 770 REV 000A VERTICAL WINDLASSES EN INSTALLATION AND USER S MANUAL Other languages available by scanning the QR code on the back of this manual or on the label on the product...

Страница 2: ......

Страница 3: ...allation 6 2 2 Recommended Quick accessories not included 6 3 Introduction 6 3 0 Important notes 6 3 1 Precautions 7 3 2 Precautions for the installer 7 4 Installation 7 4 0 Installation requirements...

Страница 4: ......

Страница 5: ...ecific circuit breaker for direct current DC and delayed circuit breaker thermal magnetic or hydraulic magnetic 5 On request studs can be supplied for greater deck thicknesses 6 Only on request BARBOT...

Страница 6: ...push button panel HRC 1002 Foot switch 900 Hydraulic magnetic circuit breaker WCB Anchor chain counter CHC 1102M CHC 1202M Control system via RRC radio R02 P02 H02 3 Introduction BEFORE USING THE PROD...

Страница 7: ...fixed points such as chain stopper or bollard To prevent accidental releases the anchor must be secured The windlass must not be used as sole securing device Isolate the windlass from the electrical...

Страница 8: ...o the fixing studs Connect the supply cables from the windlass to the reversing contactor unit STUD B DECK LEVEL Ensure that the upper and lower surfaces of the deck are as parallel as possible If thi...

Страница 9: ...HRC 1002 MOTOR BATTERY HYDRAULIC MAGNETIC CIRCUIT BREAKER see table on page 5 REVERSING CONTACTOR UNIT mod T6411 12 12V C A2 FOOT SWITCHES MOD 900U AND 900D BLACK BROWN BLUE BROWN BLACK BLUE A1 FUSE 4...

Страница 10: ...e The clutch B provides a link between the gypsy and the main shaft A The clutch can be released disengagement by using handle C which when inserted into bush D of the drum or into the gypsy cover 6 m...

Страница 11: ...taining screws 5 Remove the gypsy 4 Remove the clutch washer 6 Clean all the parts removed to avoid corrosion and grease with marine grease the shaft thread and the gypsy where the clutch cones rest R...

Страница 12: ...TE GYPSY DP2 5 SCREW 6 LOWER WASHER 7 CHAIN GUIDE COVER DP2 8 STUD 9 WASHER 10 SERRATED WASHER 11 NUT 12 OIL SEAL 13 BEARING 14 EXTERNAL SNAP RING 15 SHAFT DP2L 16 KEY 17 SHAFT WHEEL 18 EXTERNAL SNAP...

Страница 13: ...oduce changes to the equipment and the contents of this manual without prior notice In case of discordance or errors in translation between the translated version and the original text in the Italian...

Страница 14: ...QUICK S p A Via Piangipane 120 A 48124 Piangipane RAVENNA ITALY Tel 39 0544 415061 Fax 39 0544 415047 www quickitaly com quick quickitaly com Product serial number DP2 L 770 REV 000A...

Отзывы: