15
BOILER BX15-100 - REV007A
EN
WARNING:
Quick
®
nautic water heaters are provided
with a double thermostat with manual reset that
shuts down power supply in case of an excessive
water temperature.
If it happens, follow the instructions below:
• shut down power supply.
• Remove the protection cover (12) in order to reach
the thermostat (10).
• Push the reset button on the double thermostat (fig. 4).
• Replace on the protection cover (12).
• Switch on power supply.
WARNING:
if the high temperature safety system
switches on repeatedly, call Quick
®
service center.
MAINTENANCE
We recommend checking the magnesium anode (
A
) every
12 months.
Replace the anode if its size has been reduced significantly.
This simple and preventive maintenance will ensure a long
life of the equipment.
During wintertime, when the water heater is not
in use it should be drained using the lever of the
valve (5). This is to avoid serious damage caused
by freezing.
The overpressure release device must be activated regular-
ly to remove calcium deposits and to ensure that it is not
blocked.
Periodically check the joints of the water pipe installation;
check the tightness of the securing screws and replace
them in case they are worn or corroded.
Also periodically check the electrical system working order.
POS.
DESCRIPTION
CODE
1A
TANK 15L WITH HEAT EXCHANGER
M L B 1 5 2 6 0 S 0 0 0
1B
TANK 20L WITH HEAT EXCHANGER
M L B 2 0 2 6 0 S 0 0 0
1C
TANK 25L WITH HEAT EXCHANGER
M L B 2 5 2 6 0 S 0 0 0
1D
TANK 30L WITH HEAT EXCHANGER
M L B 3 0 3 2 0 S 0 0 0
1E
TANK 40L WITH HEAT EXCHANGER
M L B 4 0 3 2 0 S 0 0 0
1F
TANK 50L WITH HEAT EXCHANGER
M L B 5 0 3 6 0 S 0 0 0
1G
TANK 60L WITH HEAT EXCHANGER
M L B 6 0 3 6 0 S 0 0 0
1H
TANK 80L WITH HEAT EXCHANGER
M L B 8 0 3 6 0 S 0 0 0
1I
TANK 100L WITH HEAT EXCHANGER
M L B 1 0 0 3 6 0 S 0 0
2
RED PLASTIC WASHER
P E C R B L R S 0 0 0 0
3
WHITE PLASTIC WASHER
P E C R B L B N C 0 0 0
4
BLUE PLASTIC WASHER
P E C R B L B L 0 0 0 0
5
RELIEF/NON RETURN VALVE
MNVALS12S68P
6
HOSE CLAMP
P B F 2 5 1 0 0 W 0 0 0
7
DISCHARGE PIPE
PVTBGM10NT00
8 A
ELEMENT GASKET
FROM S/N 100.000
P G G R E S 0 0 0 0 0 0
8 B
ELEMENT GASKET
FROM S/N 200.000
P G R M 4 3 5 0 0 0 0 0
9A
ELECTRIC ELEMENT
1200W 220V
E V R 1 2 2 2 0 N 0 0 0
9B
ELECTRIC ELEMENT
500W 220V
E V R 0 5 2 2 0 N 0 0 0
9C
ELECTRIC ELEMENT
1200W 110V
E V R 1 2 1 1 0 N 0 0 0
9D
ELECTRIC ELEMENT
600W 110V
E V R 0 6 1 1 0 N 0 0 0
10
BI-THERMOSTAT
E V T 1 5 S 0 0 0 0 0 0
11
POWER SUPPLY CABLE
E C C 3 0 1 5 0 G 0 0 0
12A
BOILER RESISTOR COVER 220V
P E C R B 2 2 0 0 0 0 0
12B
BOILER RESISTOR COVER 110V
P E C R B 1 1 0 0 0 0 0
13
NUT
MBD04MXEN000
14
GROUND CABLE TERMINAL
E J C Y 0 4 0 0 0 0 0 0
15
WASHER
M B R 0 4 X 0 0 0 0 0 0
16
SCREW 2,9 X 19
MBV02919AXCC
17A
TANK MOUNTING
BX15-BX20-BX25
MMSTBL300DR1
17B
TANK MOUNTING
BX26-BX30-BX40
MMSTBL400DR1
17C
TANK MOUNTING
BX41-BX50-BX60-BX80
MMSTBL400DR1
18
BOLT
MBV0830MXE00
19
WASHER
M B R 0 8 X 0 0 0 0 0 0
20
NUT
MBD08MXEN000
21
CABLE CLAMP
P P B L B X 0 0 0 0 0 0
22
SCREW 2,9 X 16
MBV02916AXCC
MAINTENANCE
F