background image

— 9 —

u

 

WITH THE UNIT UNPLUGGED

, place the Hydroxyl 

Generator vertically with the controls facing up and 
remove the two retaining screws as shown, one on 
each side of the plastic end cap.

v

  Gently remove the plastic end cap, screen and 

carbon filter. 

 

Remove three of the 8/32 screws holding the finger 
guard in its place and loosen the remaining screw. 
Rotate finger guard 180° so it is out of the way to 
access the UV Bulb area.

 

Loosen both socket head screws using a 5/64 
Allen key, then gently remove them by hand while 
securing the head socket. 

Replacing the UV Bulbs

When one of UV bulbs blows, you must replace both at the same time. The UV bulbs can be purchased 
through your distributor. Replace UV bulbs as follows:

Содержание 852551003203

Страница 1: ...afety and maintenance information Keep these instructions for future reference These instructions contain important safety and operating information for your Newaire HG1500 Hydroxyl Generator Please contact us directly with questions you may have regarding the safe operation and or maintenance Toll Free 1 877 646 9663 ...

Страница 2: ...Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide rea...

Страница 3: ...rain or moisture does not operate normally or has been dropped 15 WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture Do not place objects filled with water such as a vase on the apparatus 16 The AC mains plug is used as the power disconnect device and it should remain readily accessible and operable during intended use In order to completely disco...

Страница 4: ...tip Keep the eyedropper at an angle to stop the mercury from rolling back out until you can put the mercury into the plastic bag Wrap tape sticky side out around your gloved fingers and carefully use it to pick up any remaining glass or beads Check again with the flashlight to be sure that no beads of mercury remain At this point mercury beads may still be trapped in cracks or crevices on irregula...

Страница 5: ...yl generator will do the job Hydroxyls are not temperature sensitive and like higher humidity What maintenance is required Very little Simply replace the UV lamps when they burn out see page 9 and replace the carbon filters after approximately 60 days of use see page 8 You can also clean as described on page 11 Are there safety precautions to be observed Yes see pages 2 to 5 Particularly do NOT lo...

Страница 6: ... 6 Location of Controls Power Switch Plastic End Cap Fuse bottom of unit AC Cord bottom of unit Timer Knob Carrying Handle Plastic End Cap ...

Страница 7: ...ons THIS APPLIANCE MUST BE GROUNDED In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current This appliance is equipped with a cord having a grounding wire with a grounding plug The plug must be plugged into an outlet that is properly installed and grounded Plug into properly installed and grounded three prong out...

Страница 8: ... the new carbon filter then replace the screen and plastic end cap x Re insert the two screws y Repeat for the other carbon filter located on the opposite side IMPORTANT The HG1500 should never be operated without the screen or carbon filter in place Replacing the Carbon Filters After approximately 60 days of use both carbon filters should be replaced The carbon filters are located at each end of ...

Страница 9: ...ee of the 8 32 screws holding the finger guard in its place and loosen the remaining screw Rotate finger guard 180 so it is out of the way to access the UV Bulb area x Loosen both socket head screws using a 5 64 Allen key then gently remove them by hand while securing the head socket Replacing the UV Bulbs When one of UV bulbs blows you must replace both at the same time The UV bulbs can be purcha...

Страница 10: ...efully sliding lamp into lamp holder making sure to align the bottom end of the UV bulb into the bottom recess V Reconnect the power supply then reinsert socket head screws and gently tighten with 5 64 Allen key W Repeat process with the second UV lamp as they should be replaced in pairs X Rotate finger guard back in place and secure with retaining screw Make sure both screws are gently secured ...

Страница 11: ...ng To clean use a damp soapy cloth for standard cleaning WARNING Make sure the unit is unplugged before maintenance is performed WARNING UV Bulbs MUST be disposed of properly see pages 4 and 5 for details on removing the mercury containing UV bulbs at Reinsert carbon filter metal retaining screen and plastic end cap then secure with retaining screws ...

Страница 12: ... Handling and Disposal of Mercury Internal Component failure call 1 866 676 9663 for service Hydroxyl Generator is not performing well The life of the carbon filter may have been met or damaged replace both carbon filters see page 8 The life of the UV bulb may have been met or damaged If they are burnt out replace both bulbs as shown on pages 9 to 11 If broken refer to pages 4 5 for Handling and D...

Страница 13: ... BE PERFORMED BY AN AUTHORIZED WARRANTY REPAIR CENTER AT THE TIME REQUEST FOR REPAIR IS MADE EVIDENCE OF THE DATE OF PURCHASE AND DATES OF MAINTENANCE WORK MUST BE PROVIDED UPON REQUEST TRANSPORTATION COSTS SHALL BE BORNE BY THE PURCHASER OF THE EQUIPMENT THE EXPRESS WARRANTY SET FORTH HEREIN IS IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANT...

Страница 14: ...QUEENAIRE TECHNOLOGIES INC 9483 State Highway 37 Ogdensburg NY 13669 www queenaire com ...

Отзывы: