UMTS/HSPA(+) Module Series
UC200T-EM Hardware Design
UC200T-EM_Hardware_Design 51 / 68
Table 30: UC200T-EM Conducted RF Receiving Sensitivity
5.5.
Electrostatic Discharge
The module is not protected against electrostatics discharge (ESD) in general. Consequently, it is subject
to ESD handling precautions that typically apply to ESD sensitive components. Proper ESD handling and
packaging procedures must be applied throughout the processing, handling and operation of any
application that incorporates the module.
The following table shows the module electrostatics discharge characteristics.
Table 31: Electrostatics Discharge Characteristics (Temperature=25
℃
, Humidity=45%)
Frequency
Primary
Diversity
SIMO
1)
3GPP (SIMO)
EGSM900
-108dBm
NA
NA
-102dBm
DCS1800
-108dBm
NA
NA
-102dBm
WCDMA B1
-108dBm
NA
NA
-106.7dBm
WCDMA B8
-110dBm
NA
NA
-103.7dBm
Tested Points
Contact Discharge
Air Discharge
Unit
VBAT, GND
±9
±14
kV
All Antenna Interfaces
±9
±14
kV
Other Interfaces
±0.5
±1
kV