SC20-A_Manual_R1.0 Confidential / Released 34 / 49
Parameter Description
Conditions
Typ.
Unit
LTE-FDD Band13 @23.3dBm 674.84
mA
LTE-FDD Band25 @23.1dBm 760
mA
LTE-FDD Band26 @23.2dBm 731
mA
7.6. Electrostatic Discharge
Table 21: Electrostatic Discharge Characteristics ( Temperature: 25
℃
, Humidity: 45%)
The module is not protected against electrostatic discharge (ESD) in general. Consequently, it should be
subject to ESD handling precautions that are typically applied to ESD sensitive components. Proper ESD
handling and packaging procedures must be applied throughout the processing, handling and operation
of any application that incorporates the module.
The following table shows the module electrostatic discharge characteristics.
Tested Points
Contact Discharge
Air Discharge
Unit
VBAT, GND
+/-5
+/-10
KV
All Antenna Interfaces
+/-5
+/-10
KV
USB Interfaces
+/-0.5
+/-1
KV
Other Interfaces
+/-0.5
+/-1
KV