GSM/GPRS/GNSS Module Series
MC60 Series Hardware Design
MC60_Series_Hardware_Design Confidential / Released 48 / 114
3.7.2.2. Power down Module Using AT Command
It is also a safe way to turn off the module via AT command
AT+QPOWD=1
. This command will let the
module log off from the network and allow the firmware to save important data before completely
disconnecting the power supply.
Before the completion of the power down procedure, the module sends out the result code shown below:
NORMAL POWER DOWN
After that moment, no further AT commands can be executed. And then the module enters into the power
down mode.
Please refer to
document [1]
for details about the AT command
AT+QPOWD
.
3.7.2.3. Power down GNSS part Alone Using AT Command
It is a safe way to turn off the GNSS part alone via AT command
AT+QGNSSC=0
. The power down
scenario for GNSS part is illustrated in the following figure.
VBAT
VDD_EXT
(OUTPUT)
GNSS_VCC_EN
GNSS_VCC
GSM PART STATUS
RUNNING
GNSS PART STATUS
RUNNING
OFF
Send AT+QGNSSC=0
Through GSM UART Port
Figure 20: Turn-off Timing of GNSS part by Using AT Command
Quectel
Confidential