GSM/GPRS Module
M35
AT Commands Manual
M35
_AT_Commands_Manual Confidential / Released
76
/
186
SYNC
Synchronous transparent
REL ASYNC
Asynchronous non-transparent
REL SYNC
Synchronous non-transparent
FAX
Facsimile
VOICE
Voice
Example
AT+CRC=1
// Enable extended format
OK
+CRING: VOICE
// Indicate incoming call to the TE
ATH
OK
AT+CRC=0
// Disable extended format
OK
RING
// Indicate incoming call to the TE
ATH
OK
7.18. AT+CRLP Select Radio Link Protocol Parameter
AT+CRLP Select Radio Link Protocol Parameter
Test Command
AT+CRLP=?
Response
TA returns values supported. RLP (Radio Link Protocol)
versions 0 and 1 share the same parameter set. TA returns
only one line for this set (where
<verx>
is not present).
+CRLP:
(list of supported
<iws>
s),(list of supported
<mws>
s),(list of supported
<T1>
s),(list of supported
<N2>
s),(list of supported
<ver1>
s),(list of supported
<T4>
s)
OK
Read Command
AT+CRLP?
Response
TA returns current settings for RLP version. RLP versions 0
and 1 share the same parameter set. TA returns only one line
for this set (where
<verx>
is not present).
+CRLP: <iws>,<mws>,<T1>,<N2>,<ver1>,<T4>
OK
Write Command
Response