2.16. ATX Set CONNECT Result Code Format and Monitor Call Progress
Parameter
2.17. ATZ Set all Current Parameters to User Defined Profile
Parameter
ATX Set CONNECT Result Code Format and Monitor Call Progress
Execution Command
ATX<value>
Response
This parameter setting determines whether or not the TA
detected the presence of dial tone and busy signal and
whether or not TA transmits particular result codes.
OK
Reference
V.25ter
<value>
0
CONNECT
result code only returned, dial tone and
busy detection are both disabled
1
CONNECT<text>
result code only returned, dial tone and
busy detection are both disabled
2
CONNECT<text>
result code returned, dial tone detection
is enabled, busy detection is disabled
3
CONNECT<text>
result code returned, dial tone detection
is disabled, busy detection is enabled
4
CONNECT<text>
result code returned, dial tone and
busy detection are both enabled
ATZ Set all Current Parameters to User Defined Profile
Execution Command
ATZ[<value>]
Response
TA sets all current parameters to the user defined profile.
OK
Reference
V.25ter
<value>
0
Reset to profile number 0