GSM/GPRS Module
M35 AT Commands Manual
M35_AT_Commands_Manual Confidential / Released 69 /
186
Parameter
No effect in GSM
7.9. ATS7 Set Number of Seconds to Wait for Connection Completion
Parameter
1. If called party has specified a high value for
ATS0=<n>
, call setup may fail.
2. The correlation between
ATS7
and
ATS0
is important, for example: Call may fail if
ATS7=30
and
ATS0=20
.
3.
ATS7
is only applicable to data call.
Write Command
ATS6=<n>
Response
OK
Reference
V.25ter
<n>
0-2-10
Number of seconds to wait before blind dialing
ATS7 Set Number of Seconds to Wait for Connection Completion
Read Command
ATS7?
Response
<n>
OK
Write Command
ATS7=<n>
Response
This parameter setting determines the amount of time to wait
for the connection completion in case of answering or
originating a call.
OK
Reference
V.25ter
<n>
1-60-255 Number of seconds to wait for connection completion
NOTE
NOTES