M10 AT Commands Set
M10_ATC_V1.01
- 147 -
Parameter
See Write Command
Write Command
AT+QIHEAD=<
mode>
Response
OK
ERROR
Parameter
<mode>
a numeric parameter which indicates whether add an IP
header before received data or not
0 not add IP header
1 add IP header, the format is “+IPD(data length):”
Reference
Note
7.2.14 AT+QIAUTOS Set Auto Sending Timer
AT+QIAUTOS Set Auto Sending Timer
Test Command
AT+QIAUTOS=
?
Response
+QIAUTOS:
(list of supported <
mode
>s)
OK
Parameter
See Write Command
Read Command
AT+QIAUTOS?
Response
+QIAUTOS:
<mode>
OK
Parameter
See Write Command
Write Command
AT+QIAUTOS=
<mode>,<time>
Response
OK
ERROR
Parameters
<mode>
a numeric parameter which indicates whether set timer
when sending data
0 not set timer when sending data
1 Set timer when sending data
<time>
a numeric parameter which indicates the seconds after
which the data will be sent
Reference
Note
7.2.15 AT+QIPROMPT Set Prompt Of ‘>’ When Sending Data
AT+QIPROMPT Set Prompt Of ‘>’ When Sending Data
Test Command
Response
Quectel