EN
.
41
•
Group 5: Basic on/off (Triggered at reaching roller position: bottom=FF, top=0) up to 16
nodes.
When blinds reach upper position, Flush Shutter will send Basic set OFF command to
associated device and the device will turn OFF. When blinds reach down position Flush
Shutter will send Basic set ON command to associated device and the device will turn ON.
•
Group 6: Basic on/off (triggered at reaching roller position: bottom=FF, not bottom=0) up
to 16 nodes
When blinds reach down position, Flush Shutter will send Basic set ON command and the
device will turn ON. When blinds are in any position which is not down (0 %) Flush Shutter
will send Basic set OFF to associated device and the device will turn OFF.
•
Group 7: Multilevel set (Triggered at change of value of the Flush Shutter position), up to
16 nodes.
Flush shutter will set Switch multilevel command to associated device, the command is
actual position of blinds so the associated device will turn on same level as blinds are.
Example with association between Flush Shutter and dimmer, when shutters blinds reach
middle position 50 % it will send switch multilevel set 50 % command and dimmer will
turn on 50 %.
•
Group 8: Multilevel set (Triggered at changes of value of slats tilting position), up to 16
nodes. Flush Shutter device will send Switch multilevel set command to associated
device, the command is actual position of tilts.
Example with association between Flush shutter and dimmer
When shutters tilts rotate to middle position 50 % it will send switch multilevel set 50 %
command and dimmer will turn on 50 %.
•
Group 9: Multilevel sensor report (triggered at sensed different value
–
sensor sold
separately), up to 16 nodes. Flush Shutter device will send Multilevel sensor report to
associated device, this will send the information of actual temperature that was
measured with temperature sensor.
End point 1:
•
Group 1: Lifeline group, 0 nodes allowed.
Содержание Flush Shutter
Страница 3: ...EN 3 18 Warning 64 19 Regulations 64 ...
Страница 12: ...EN 12 Remotely control projector screen Remotely control retractable awnings Remotely control windows ...
Страница 19: ...EN 19 4 Package Contents Flush Shutter Device Installation Manual ...
Страница 21: ...EN 21 ...
Страница 25: ...EN 25 After Qubino installation ...
Страница 31: ...EN 31 Step 2 Switch of the power supply Step 3 Connect the temperature sensor as shown below ...
Страница 32: ...EN 32 Step 4 Place the temperature sensor in the switch box Step 5 Turn the fuse on ...
Страница 33: ...EN 33 Step 6 Re include the device to your network ...
Страница 34: ...EN 34 Step 7 Start using the temperature sensor in connection with your device ...