For safe operation use S (Service) button when the module connected to 24VDC SELV power
supply. For DC wirring connect (+) terminal to N and (
–
) terminal to L.
Electrical diagram 24VDC
The durability of the device depends on the load connected. Resistive loads (light bulbs, etc.) and
loads that consume up to
4A, the product’s lifespan exceeds 70,000 toggles.
OVERLOAD PROTECTION
Max Power Limit is automatically set by software. When the current exceeds 4A for more than 5
seconds, the load is automatically turned off. An "overload detected" notification is sent to your
gateway/hub. To reactivate the device, power supply must be turned OFF and ON again.