background image

QUATRO    

Air Technologies Inc. 

------------------------------------------------------------

We Make Clean Air

 ----------------------------------------------------------

 

30 Hymus Boulevard, Montreal, Quebec, H9R 1C9     Tel.: (514) 630-4444   Fax: (514) 630-4454   website: 

www.QUATRO-air.com

   [email protected] 

Remote Operation 

If choosing the Dry Contact (closed contact) remote option, connect the black and red wires to anything that can close a 
contact and short these 2 wires together.   

 

If choosing the 1-30V AC/DC remote option, connect the white & the green wires to the remote signal. RESPECT THE 
INDICATED POLARITY WHEN MAKING THIS CONNECTION. 

DO NOT EXCEED 30V AC/DC. 

 

To enable the remote system startup for either remote option, first plug the system into power and then connect remote 
cable. Then simply have the other piece of equipment close (short) the dry contact or supply a remote control voltage. 
When the unit is stopped the Quatro System

 

will shut down after a short delay.

 

 

 

After Remote Sensing Has Been Activated 
If the unit is RECEIVING a remote signal: “System

 

ON” & “Remote ON” Lights will be FULLY Illuminated 

If the unit is WAITING FOR a remote signal: “System ON”  will be OFF & “Remote ON” Lights will be FLASHING 
Unplugging the power cord will automatically deactivate Remote Sensing Feature. 

 

Remote Status 

The System can output status signals to you equipment.  

 

The Run Signal contact is CLOSED whenever the system is turned on (motor(s) are functioning).  
The contact is OPEN when the unit is turned off (motor(s) are not functioning). This includes when the unit goes into 
Remote/Standby & if the unit shuts down due to a problem. 
Run signal will NOT open when the motor(s) shut off for a filter cleaning when operating in “Online” filter cleaning mode.

  

Critical Filter Pressure Alarms (high & low pressure) will OPEN the Run Signal and shut the motor(s) off.   

 

The Fault Signal can be used either with a Normally Open (NO) or Normally Closed (NC) contact depending on which wire 
you choose to use (see diagram on previous page). 
When there ARE NO alarm conditions present the NO contact will remain open and the NC contact will remain closed. 
When there ARE alarm conditions the NO contact will CLOSE and the NC contact will OPEN. 
ALL LEVELS of Filter & Motor(s) service alarms will trip the Fault Signal. 

 

The Quatro Run Signal can only shut down the piece of equipment controlling it remotely if the piece of equipment 
supports that function. The piece of equipment must be set or programmed to shut itself off when the Quatro Run 
signal is OPENED. Contact your

 

equipment manufacturer to verify if your equipment supports that function.

 

 

The status signals can either return a “signal” provided by your equipment or output a 12VDC+ or 12VDC- depending on 
how the AE427 remote cable is wired. The Quatro System uses a single “common” for both the Run & Fault Signals.  

 

To return a “signal” connect your signal to the Brown wire (Pin 5).  
The “returned” Run signal is available on the Violet wire (Pin 9). 
The “returned” Fault NC (Normally Closed) is available on the Blue wire (Pin 6). 
The “returned” Fault NO (Normally Open) is available on the Orange wire (Pin 7). 

 

To be supplied with a 12vdc signal where the + is being switched connect the Yellow Wire (Pin 8) to the Brown wire (Pin 5). 
The 12VDC+ Run signal is available across the Violet wire (Pin 9+) & the Black Wire (Pin 1-).  
The 12VDC+ Fault NC (Normally Closed) is available across the Blue wire (Pin 6+) & the Black Wire (Pin 1-).  
The 12VDC+ Fault NO (Normally Open) is available across the Orange wire (Pin 7+) & the Black Wire (Pin 1-).  
Any combination of the Dry Contact, Run Signal & Fault Signal being used means the Black Wire (Pin 1) must be shared.  

 

To be supplied with a 12vdc signal where the - is being switched connect the Black Wire (Pin 1) to the Brown wire (Pin 5). 
The 12VDC- Run signal is available across the Violet wire (Pin 9-) & the Yellow Wire (Pin 8+).  
The 12VDC+ Fault NC (Normally Closed) is available across the Blue wire (Pin 6-) & the Yellow Wire (Pin 8+) 
The 12VDC+ Fault NO (Normally Open) is available across the Orange wire (Pin 7-) & the Yellow Wire (Pin 8+).  
Any combination of the Dry Contact, Run Signal & Fault Signal being used means the Black Wire (Pin 1) must be shared. 

 

Your “signal” will be managed as indicated on the table below. The combination of the Run & Fault Signals can tell you if 
the unit is still running but has an alarm condition or if there is an alarm condition and the unit has shut down completely.  

 

Run Signal 

Contact 

Fault Signal 

Contact 

Condition 

Closed NC: 

Closed 

NO: Open 

Unit Is Operating Normally 

Closed NC: 

Open 

NO: Closed 

Unit Is Operating Normally 

Motors or Filters Will Require Service Soon 

See QUATRO System Control Panel & LED Diagnostic Table For More Info  

Open NC: 

Open 

NO: Closed 

Unit Has Shut Down 

 Motors or Filters Require Service Immediately 

See QUATRO System Control Panel & LED Diagnostic Table For More Info 

Содержание Premium 82B5

Страница 1: ...on M THIS MA IN A SAF TAINS CR WHICH IF TO THE S Make Clean A 4 Fax 514 630 AF800 S ine Du Mainten NUAL BE FE PLACE RITICAL O NOT FOL SYSTYEM Air 0 4454 website Series ust C nance EFORE O E FOR FU OPE...

Страница 2: ...re to use proper voltage as indicated on the system To reduce the risk of electric shock do not expose to excessive moisture water or rain Use only on a grounded electrical circuit Do not install or o...

Страница 3: ...Status Cond ft touch Powe lter s and mo the following We M 514 630 4444 ESS ALL FILT able They wil tion for more ff switch and e face of the p st acceptable CTION OF TH outlet that is co witches the p...

Страница 4: ...4 630 4444 ours OPERAT uted alarms s e same time W TED mute wi e unit is in op e 8 hour mute Make Clean A 4 Fax 514 630 TING TIME A stay SOLID T When the but ll disable itse peration e the balance Air...

Страница 5: ...nd Filter Cleaning Filter Service Replacement Instructions L3 Flashing Slowly Beep Every Hour Filter Pressure Near Critical Service Becoming Urgent Replace Filters Continued Operation May Result In Un...

Страница 6: ...the FLOW peration man sure compen rols will autom ng dirty or a s the speed to not adjust blo e Status with other pie s made using plications Con act 1 30V A RO System s omatic remote ble when the he...

Страница 7: ...ely if the piece of equipment supports that function The piece of equipment must be set or programmed to shut itself off when the Quatro Run signal is OPENED Contact your equipment manufacturer to ver...

Страница 8: ...IN We M 514 630 4444 MENT Alerts iSer WLY some of ce the odor fi over anks of filter e repeated fo GEL or onto A filter Part e gasket facin rmance Filter Part F include a Dus e dust filter ju popular...

Страница 9: ...sidere arranty Period ange Motor Acc Panel We M 514 630 4444 6 Pack 12 Pack 12 Pack 25 Pack ed 2 Required quired nt Kit ll many filter seq pplications Ve ded Filter Change Every 3 Months Every 6 Month...

Страница 10: ...Se R button while ops FLASHIN e Motor s Ale 20 minutes to orSafe Brush Pa AB117 R 3 motors It tay in sync We M 514 630 4444 rushes Quick Change kly they shoul an be change poses only E FROM UNI 2 1 M...

Страница 11: ...tion in syste ed filter s s not in place impeller cont bearing failur ies Controls We M 514 630 4444 S BEFORE S s panel r holding the m the old moto the installatio FOR INFINIT h contacting e 2 Infini...

Страница 12: ...oration is authorised to assume for QUATRO any other liability in connection with the sale of these goods Equipment parts and material manufactured by others and incorporated in QUATRO s equipment are...

Страница 13: ...30 Hymus s Boulevard Mo ntreal Quebec H9R 1C9 Tel We M 514 630 4444 Make Clean A 4 Fax 514 630 Air 0 4454 website e www QUATRO Q O air com info QUATRO Air Technologies QUATRO air co O Inc m...

Страница 14: ...30 Hymus s Boulevard Mo ntreal Quebec H9R 1C9 Tel We M 514 630 4444 Make Clean A 4 Fax 514 630 Air 0 4454 website e www QUATRO Q O air com info QUATRO Air Technologies QUATRO air co O Inc m...

Страница 15: ...30 Hymus s Boulevard Mo ntreal Quebec H9R 1C9 Tel We M 514 630 4444 Make Clean A 4 Fax 514 630 Air 0 4454 website e www QUATRO Q O air com info QUATRO Air Technologies QUATRO air co O Inc m...

Отзывы: