30 Hymus
6- F
LED
If “Se
If “Se
Filter
Acce
SPH
instal
befor
Insta
1
st
filt
2
nd
fil
Place
crush
3
rd
filt
OPTI
125.
the co
The a
on th
Dispo
and l
Odor
The o
FOR
If the
Rese
1
2
3
4
5
6
7
8
----------------
s Boulevard, Mo
ILTER SER
Diagnostic T
ervice Filter(s
ervice Filter(s
r Access
ss to all the fi
& AF800 sy
llation of ONE
re running the
ll filters in the
ter to be lowe
ter to be lowe
e the Dust Filt
hed by the cov
ter to be lowe
IONAL filters:
The Dust Pad
over as pictur
above instru
he inside of t
osal of both o
egal disposal
r Filter Refilli
odor filter doe
SYSTEMS W
“Service Filte
etting “Servic
1- Ensure filt
2- Plug powe
3- Press & h
4- Hold for 1
5- You are n
6- Press SPE
7- Press & H
8- Release, w
------------------
ntreal, Quebec,
RVICE & R
Table - “Serv
)” alert is FLA
)” alert is ON
lters are throu
ystems have
E bank of filter
e system.
following seq
red into the LA
ered into place
ter Support F
ver and poor s
ered into place
Your filter se
d gets placed
red above.
uctions are fo
he access do
odor and parti
l of spent filte
ng
s not have to
WITH iSERIES
ers” LED does
ce Filter(s)”
ter access do
er back to the
old SPEED U
0+ seconds,
ow in RESET
EED DN (2 T
HOLD POWER
when LED sto
------------------
H9R 1C9 Tel.
EPLACEM
vice Filter(s)”
ASHING SLOW
SOLID replac
ugh the top co
2 identical b
rs and must b
quence:
ASER BLUE
e is the HEPA
rame with the
system perfor
e is the Dust F
equence may
d on top of the
or the most p
oor. This filte
culate filters i
ers.
be replaced.
S CONTROLS
s not go out on
Alert
oor is closed
e unit
UP & DN simu
when panel is
T MENU, in th
imes) until
“S
R button while
ops FLASHIN
----------
We M
: (514) 630-4444
MENT
” Alerts (iSer
WLY some of
ce the odor fi
over.
anks of filter
e repeated fo
GEL (or onto
A filter. Part #:
e gasket facin
rmance.
Filter Part # : F
include a Dus
e dust filter ju
popular filter
er sequence c
is the respons
It can be refil
S:
n its own afte
ultaneously un
s beeping con
his condition,
Service Filter
e
“Service F
NG & stops BE
Laser B
Gel
Filter Top
Access Cover
Optional Pre-Fil
Knock Out Pad
PN: F166-125
STAGE 1
Make Clean A
4 Fax: (514) 630
ries Controls
f the particula
lter.
s installed be
or the second
gasket) is the
F074
ng down. Failu
F071
st Pad PN: F0
ust before inst
r sequence. F
can be custo
sibility of the e
led with new f
r changing the
ntil unit BEEP
ntinuously, re
“System ON”
r(s)”
LED is F
ilter(s)”
LED
EEPING
Blue
lter
Air
------------
0-4454 website
s)
ate filters are
eside each o
bank. ALWAY
e chemical filte
ure to install t
069-220 (Not
talling the cov
For all other
omized for yo
end user. Ple
filtration medi
e filters follow
PS
elease buttons
” Led is FLAS
FLASHING
D is FLASHING
------------------
e:
www.QUATRO
getting clogg
other. The ins
YS make sure
er. Part #: AG
the frame will
t Pictured) or
ver. The Knoc
r filter sequen
our applicatio
ease contact l
a.
w the reset pro
s
SHING QUICK
G & unit is BE
Q
------------------
O-air.com
info@
ed and need
structions bel
e all of the filte
G097.
result in the
a Knock Out
ck Out Pad g
nces follow t
on.
local authoriti
ocedure below
KLY
EEPING cont
D
S
QUATRO
Air Technologies
------------
@QUATRO-air.co
to replaced.
low are for th
ers are installe
dust filter bein
Pad PN: F16
ets installed o
the filter ord
es for proper
w.
inuously
Dust Filter
Support Frame
Dust Filter
PN: F071
STAGE 2
HEPA Filter
PN: F074
STAGE 3
Odor Filter
PN: AG097
STAGE 4
Optional Pre-Fi
Knock Out Pad
PN: F166-125
STAGE 1
O
Inc.
m
he
ed
ng
66-
on
er
lter