Page 8
© Quatro Air Technologies| JULY 2019 | All rights reserved |
Jet-Stream Tall Operation & Maintenance Manual
i Series Controls
To mute:
•
Press
SPD UP
and
DN
quickly at the same time .
When the buttons are released the alarm(s) will mute and L1 will start flashing. Alarm LED will go SOLID.
If there are any additional alarms when MUTED, mute will disable itself until muted again, then BOTH alarms will be
muted .
Muted alarms will only be displayed while the unit is in operation .
If the unit is turned off and then on during the 8 hour mute, the balance of the 8 hour mute will continue after the unit is
turned on again .
Light Diagnostics Table (Rev 17.0 and Higher)
Light
(LED)
Status
Audible
Alert
Condition
Description/Action
System
ON
LED 1
(L1)
SOLID
Unit is ON
N/A
Fading
IN-OUT
Temporary ON Mode
POWER Button Had Been Used To Temporarily Turn
Unit On While In Remote Mode
See
Temporary On Mode
on page 14
Flashing
Slowly
AUDIBLE ALERT MUTED
Alarm Condition MUTED, See L2 OR L3 For Specific
Alarm Condition
Service Motors
LED 2 (L2)
SOLID
Beep Every
4 Hrs
Motor(s) Will Soon Need Service
“Quick Change” Brush Motor(s) WILL SOON Require
Brush Replacement
Infinity Brush Motor(s) WILL SOON Require Complete
Replacement
Brushless Motor Is Almost At The End Of The Predict-
ed Service Life
RESET ALERT After Service
See "
Motor Service and Replacement"
on page 20
SOLID
Beep Every
15 Min
Motor(s) Service Becoming Urgent
“Quick Change” Brush Motors ONLY: Replace Brush-
es ASAP And
RESET ALERT
See
"Motor Service and Replacement"
on page 20
SOLID
Beep Every
5 Min
Motor(s) Service
Required
IMMEDIATELY
“Quick Change” Brush Motors ONLY: Replace Brush-
es IMMEDIATELY And
RESET ALERT
See
"Motor Service and Replacement"
on page 20
SOLID
Motor Alarm Muted
L1 Flashing Slowly
Replace Brushes OR Motor(s) ASAP And RESET
ALERT
Alarm Mute Details On Previous Page
See
"Motor Service and Replacement
" on page 20