Page 10
© Quatro Air Technologies| JULY 2019 | All rights reserved |
Jet-Stream Tall Operation & Maintenance Manual
i Series Controls
Normal (Manual) Operation
Manual operation of the unit is accomplished by using the (Red)
POWER
button .
Variable Digital Speed Control and AUTOFLOW
Speed control is available in all modes of operation (manual and automatic) and is adjusted with the
UP and DOWN
arrows .
AUTOFLOW
is an automatic system pressure compensation system . After setting the minimum speed required to
properly evacuate your equipment, the controls will automatically increase the motor speed to compensate for the
increased pressure as a result of filters getting dirty or a system blockage until maximum speed is reached. After a
filter change, system will automatically decrease the speed to the original set point. Please verify that you are achieving
adequate ventilation after a filter change. If not, adjust blower speed.
Remote Operation
Remote Operation Mode simply means that the ON/OFF button on the control panel will be temporarily disabled if the
system is receiving a signal form a remote source to operate .
To enable the remote system startup simply supply a remote signal after the power supply and
remote cable are connected to the system . The
Jet-Stream System
will respond by illuminating LED 1 (System On) and
LED 5 (Remote/Standby) .
Whenever the remote signal is supplied the unit will instantly start, when the remote signal is stopped the unit will stop
after a 30 second delay .
Set the shut off delay in your control software to the shortest possible interval. The Jet-Stream System has a 30-second
delay that cannot be turned off.