Filter Service and Replacement
3 . Remove the two nuts and lift out the grill .
The HEPA filter is now visible.
4 . Replace your filters using the appropriate parts.
NOTE:
Disposal of both odor and particulate filters is the responsibility of the end user. Please contact local authorities
for proper and legal disposal of spent filters.
Resetting Service Filters Alert
If the
Service Filters
LED does not extinguish on its own after changing the filters, follow this reset procedure.
1 . Ensure filter access door is closed.
2 . Plug power back to the unit .
3 . When you Press “POWER”, MOTOR WILL START .
4 . While motor is operating, press and hold SPD UP and SPD DN simultaneously until unit beeps .
Hold for 10+ seconds; when panel is beeping continuously, release buttons .
In this condition, “System ON” LED is FLASHING quickly .
5 . Press SPD DN until “Service Filters” LED is FLASHING .