removed and/ or inserted from the system as desired. On each insertion into the
PCMCIA socket, the SSP-200/300 will be automatically reconfigured according to
the command line options.
2.1.2 Command Line Options
The SSP-200/300 Client Driver accepts up to eight command line arguments from the user to
determine the configuration of theSSP-200/300. If any arguments are provided, the Client Driver
will attempt to configure any SSP-200/300s with the options specified in the order they are
entered on the command line. Each argument must be enclosed in parenthesis and must be
separated from other arguments by a
space
on the command line. Within each argument, any or
all of the following parameters may be specified using a
comma (no spaces)
to separate each
parameter:
B
address
specifies a the base I/O address of the SSP-200/300in hexadecimal. This address
must reside on an even 8-byte boundary. If this option is omitted, a base address will
be assigned by Card and Socket Services.
I
irq
specifies the interrupt level (IRQ) of the SSP-200/300in decimal.
irq
must be one of
the following values: 3, 4, 5, 7, 9, 10, 11, 12, 14, 15, or 0 if no IRQ is desired. If this
option is omitted, an interrupt level will be assigned by Card and Socket Services.
S
socket
specifies which PCMCIA socket the SSP-200/300must be inserted into for this
configuration argument to be used.
socket
must be in the range 0 - 15. If this option
is omitted, the configuration argument will apply to SSP-200/300s inserted into any
socket.
Odriver
specifies RS-422/485 output driver enable option for the SSP-200/300 port. The
SSP-200/300’s port may be configured for either full duplex or half duplex
operation with this option. If this option is omitted, the default setting is the
RS-422/485 port is configured for full duplex operation with the RS-422/485 output
drivers always enabled. In half duplex mode, the RS-422/485 transmitter may be
enabled and disabled via the RTS (request to send) or DTR (data terminal ready)
signals. Both RTS and DTR are controlled through the Modem Control Register of
the 16750. See the
Hardware Information
section for more information.
DOS/Windows 3.x
2-4
Содержание SSP-200
Страница 6: ...This page intentionally left blank 2 1 SSP 200 300 Rev I and later User s Manual ...
Страница 18: ...This page intentionally left blank 3 1 SSP 200 300 Rev I and later User s Manual ...
Страница 24: ...This page intentionally left blank 4 1 SSP 200 300 Rev I and later User s Manual ...
Страница 26: ...4 Double click Serial Port Adapters 5 Double click Drivers 4 3 SSP 200 300 Rev I and later User s Manual ...
Страница 27: ...6 Double click on Windows 2000 XP for PCI PCMCIA ISA 7 Click on qserbrd and select open Windows 2000 4 4 ...
Страница 31: ...Windows 2000 4 8 ...
Страница 33: ...Windows 2000 4 10 ...
Страница 38: ...This page intentionally left blank 5 1 SSP 200 300 Rev I and later User s Manual ...
Страница 48: ...This page intentionally left blank 7 1 SSP 200 300 Rev I and later User s Manual ...
Страница 50: ...This page intentionally left blank 8 1 SSP 200 300 Rev I and later User s Manual ...
Страница 52: ...SSP 200 300 User s Manual Revision 3 12 March 2004 P N 940 0075 312 Quatech Inc ...