2.2.1.6 Example 6
SSP231EN.EXE (s0,b300,i5,r)
In example 6, the Enabler will release the configuration used by the SSP-200/300 in socket 0
using a configuration memory window at segment D000. The base address and IRQ parameters
are ignored and may be omitted.
2.2.1.7 Example 7
SSP231EN.EXE (s1,r,wcc)
In example 7, the Enabler will release the configuration used by the SSP-200/300 in socket 1
using a configuration memory window at segment CC00.
2.2.2 Common Problems
Memory Range Exclusion:
The Enabler requires a region of high DOS memory when configuring aSSP-200/300. This
region is 1000H bytes (4KB) long and by default begins at address D0000H (the default address
may be changed using the "W" option). If a memory manager such as EMM386, QEMM, or
386Max is installed on the system, this region of DOS memory must be excluded from the
memory manager's control. Consult the documentation provided with the memory manager
software for instructions on how to exclude this memory region.
Furthermore, some systems use the high memory area for BIOS shadowing to improve overall
system performance. In order for the Enabler to operate, any BIOS shadowing must be disabled
in the address range specified for the configuration window. BIOS shadowing can usually be
disabled through the system's CMOS setup utility.
Socket Numbers:
The Enabler requires the SSP-200/300's socket number to be specified on the command line and
the SSP-200/300 must be inserted into the socket before the Enabler is invoked. Some vendors
number their sockets from 1 to N while other vendors number their sockets from 0 to N-1. For
theSSP-200/300 Enabler, the lowest socket number in the system is designated socket 0.
Card and Socket Services Software:
In order to use the SSP-200/300 Enabler for DOS, the system MUST NOT be configured with
Card and Socket Services software. If a Card and Socket Services software is installed, the
Enabler may interfere with its operation and with the device(s) it controls. For systems
configured with Card and Socket Services, the SSP-200/300 Client Driver is the recommended
method of configuration.
DOS/Windows 3.x
2-12
Содержание SSP-200
Страница 6: ...This page intentionally left blank 2 1 SSP 200 300 Rev I and later User s Manual ...
Страница 18: ...This page intentionally left blank 3 1 SSP 200 300 Rev I and later User s Manual ...
Страница 24: ...This page intentionally left blank 4 1 SSP 200 300 Rev I and later User s Manual ...
Страница 26: ...4 Double click Serial Port Adapters 5 Double click Drivers 4 3 SSP 200 300 Rev I and later User s Manual ...
Страница 27: ...6 Double click on Windows 2000 XP for PCI PCMCIA ISA 7 Click on qserbrd and select open Windows 2000 4 4 ...
Страница 31: ...Windows 2000 4 8 ...
Страница 33: ...Windows 2000 4 10 ...
Страница 38: ...This page intentionally left blank 5 1 SSP 200 300 Rev I and later User s Manual ...
Страница 48: ...This page intentionally left blank 7 1 SSP 200 300 Rev I and later User s Manual ...
Страница 50: ...This page intentionally left blank 8 1 SSP 200 300 Rev I and later User s Manual ...
Страница 52: ...SSP 200 300 User s Manual Revision 3 12 March 2004 P N 940 0075 312 Quatech Inc ...