Section 1:   

Introduction

Page 9

Copy Parameters Field

The Copy Parameter field is used to transfer the value of one drive parameter to another. Up to twenty parameter
copies  can exist within a single Copy Parameter field.

If 

Execute

 is set to 

On Select

 then the text  that is entered when the field is created will be displayed on the 2800

when the screen is displayed. If 

Execute

 is set to 

Link ID

 then the text that is entered when the field is created will

never be displayed. When the 

Execute

 method is 

On Select

, moving the focus, via the 

Select

 key, to this field

and pressing the 

Enter

 key will cause the copy operations to execute. When a screen is first opened the various

field  types that make up the screen go through an initialization procedure. This procedure places associated text
on the display and opens connections to the communication driver if the field type is a data access field such as a
Copy Parameter field.

If the 

Execute

 method selected for a Copy Parameter field is an 

As LinkID

 then the initialization procedure and

operation of the field are changed. A connection to the communication driver is still made but the field text is not
shown on the 2800 display and the field is not selectable using the 

Select

 key. A pointer to the Copy list is stored

in the internal memory of the 2800. To cause the field to execute a reference to it must be included within a
Recipe. This is done using the Copy Link ID parameter found within the Data Reference list. When the Copy Link
ID parameter is encountered within an executing Recipe field the execution process is transferred to the copy
parameter firmware which executes the copy parameter list. Once completed the execution process is returned to
the Recipe field. Within ScreenMaker 2000K the text associated with a Copy Parameter field is always shown,
must be at least one character, and may not be covered by another data access field. Once an 

As LinkID

 Copy

Parameter field is initialized within a screen the pointer to it which is stored within the 2800 memory is maintained
until power is removed or another 

As LinkID

 Copy Parameter of the same number is initialized. Because of this

you can initialize an 

As LinkID

 Copy Parameter field in one screen then reference it via a Recipe field in a

different screen.

PM2800U3K Revision 4

Содержание 2800

Страница 1: ...ill QUARTECH CORPORATION be responsible or liable for any damage including indirect or consequential losses resulting from the use misuse or application of the unit The text illustrations charts and e...

Страница 2: ...nt serial number prior to 55134 24 Appendix A Electrical Mechanical Specifications 25 DIP Switch assignments 25 2136 File Download Cable 27 2161Communication Cables RS 232 28 2162Communication Cables...

Страница 3: ...on every screen The function keys can be custom labeled with a slip in legend tag easily created using LegendMaker software The 2800 utilizes Flash nonvolatile memory the threat of losing the customiz...

Страница 4: ...ype variable such as Index Distance please be aware of the following If a decimal value is specified as shown here Dbl Decimal 3 then the entry and display of the variable is treated as a floating poi...

Страница 5: ...value to revolutions per minute RPM Scale Value 1 Counts per Revolution 60 Scale Value 1 8 000 60 Assume encoder producing 8 000 counts per revolution Scale Value 1 133 33333 Scale Value 0 0075 or 7 5...

Страница 6: ...dition of the two values exceeds the limit value then a warning message is displayed and the variable in the Ultra Drive is left unchanged Focus in not automatically removed from the field so that the...

Страница 7: ...ey A pointer to the Recipe is stored in the internal memory of the 2800 To cause the Recipe items to be downloaded to the Ultra this Recipe fields Link ID must be included within another Recipe This i...

Страница 8: ...modify Moving the focus via the Select key to the field and pressing the Enter key will cause the bits to be complimented by the 2800 How the Bit Status determines which string to display Example 1 D...

Страница 9: ...esults 0000 0000 0000 0000 Result does not match Data Value so the field text will change to START Lets try the opposite case Assume the results of example two the field is currently displaying START...

Страница 10: ...to 25 Value Text Strings can be specified Entry is allowed with this field After selecting this field the Next and Prev keys can be used to scroll through the text strings When the desired text string...

Страница 11: ...f the field are changed A connection to the communication driver is still made but the field text is not shown on the 2800 display and the field is not selectable using the Select key A pointer to the...

Страница 12: ...r The If Trigger field will continuously monitor the selected parameter The value read for the assigned parameter will be ANDed with the Mask Value then the selected Trigger If test will be ran using...

Страница 13: ...rtech cable 2136 10 The specifications for this cable can be found in Appendix A Prepare the computer for download by selecting the Communications heading then Download Communication Interface from th...

Страница 14: ...key on the 2800 or if a serial communication link can not be established The Firmware Download dialog will display if a successful serial link is established From this dialog select Start Download Wi...

Страница 15: ...second step is to download a Project File The file is downloaded to the 2800 using ScreenMaker 2000k configuration software running on your personal computer To perform a download the project must be...

Страница 16: ...use the 2800 to perform a warm boot which is just like re powering If the 2800 is ready then click the Connect button on the Connect to the 2800 dialog The following dialog will display If this is the...

Страница 17: ...s can write to a screen trigger word A function key can be configured to write to a trigger word A Data Set field can be configured to write to a trigger word But why use two trigger words The use of...

Страница 18: ...bers can be attached one to the Next key and one to the Prev key If a value of zero is set for the link number then the key will be ignored If a legal screen number is set then pressing the key will c...

Страница 19: ...s will be removed from this field and the cursor will move off screen If more than one variable is specified the message WRITING RECIPE DATA will appear on the display until the process is complete If...

Страница 20: ...will pop up that prompts them for the lock code Using the Lock key to deactivate a lock code allows the operator to access any field that uses that lock code with out re entering it each time the fiel...

Страница 21: ...cted When the F1 key is pressed the 2800 will write the value 1 to the Drive This is the enabled state When the key is release no action will be taken Example 2 Assume Data Value least significant bit...

Страница 22: ...value of the Velocity Setpoint variable is read from the Ultra Drive If the current value is equal to the specified value then the value zero is written to the Ultra Drive If the current value does no...

Страница 23: ...rive status request When multiple drives are assigned the 2800 will rotate through the assigned nodes one every five seconds If a drive is reported to be faulted then the associated screen will be tri...

Страница 24: ...code This is the pop up security screen The operator must enter all four characters of the lock code A lock code is comprised of the characters zero through nine the minus sign and the decimal point...

Страница 25: ...ck code in any screen without being required to enter the lock code The override will remain activated until the unit is restarted through either re powering or recovery from a fatal error The operato...

Страница 26: ...taneously You must not be editing a variable field to activate this mode This screen will display Press and hold the Select key until the desired contrast is achieved When the Select key is released t...

Страница 27: ...Section 8 LCD Contrast Adjustment Page 25 PM2800U3K Revision 4...

Страница 28: ...source power Serial Communication Port A 15 pin male D Type connector provides The RS 485 and RS 232 communication interface to Programmable Controllers Personal Computers or other host devices 4 Pos...

Страница 29: ...operations Memory Programmable Erasable Read Only Memory Flash 98 304 bytes 500 screens max Communications RS 232 RS 485 software selected Electrical 24 VDC 5 200 ma Temperature LCD 0Ec to 50Ec Operat...

Страница 30: ...2136 RS 232 communication cable between the 2800 and your personal computer If you computer does not have a serial port then use a USB Serial Adapter Quartech software and devices have been tested us...

Страница 31: ...endix A Electrical Mechanical Specification Page 29 2161 Communication Cable Use this cable to connect to the drive using RS 232 This cable is only available in a length of ten feet PM2800U3K Revision...

Страница 32: ...ical Specification Page 30 2162 Communication Cable Use this cable to connect to a single drive using RS 485 The standard length of this cable is ten feet however longer lengths can be provided upon r...

Страница 33: ...ge 31 2167 Communication Cable Use this cable along with the 9109K adapter to connect to a single or multiple drives using RS 485 The standard length of this cable is ten feet however longer lengths c...

Страница 34: ...Appendix A Electrical Mechanical Specification Page 32 2174 Communication Cable Use this cable to connect the 2800 to either input port of the Quartech 9120 Two Port Multiplexer PM2800U3K Revision 4...

Страница 35: ...e became corrupt INTERNAL RAM ERROR On power up the 2800 performs a read write verification on installed RAM memory These messages would indicate a hardware failure EXTERNAL RAM ERROR FAILSAFE CODE xx...

Страница 36: ...e focus is on a Data Set Field that is configured as Increment or Decrement and the result of this write would exceed the set limit VALUE AT MINIMUM ALL SCREENS CLOSED The value in both Trigger Words...

Отзывы: