Immunities
DLT VS160 Product Specification
8-6
September 2004
81-81275-01 REV A02
8.2.4 Surge Immunity
The tape drive meets the surge immunity limits per EN 61000–4–5: 1995 listed in
Table 8-10
.
8.2.5 Conducted Immunity
The tape drive meets the conducted immunity limits per EN 61000–4–6: 1996 listed in
Table 8-11
.
8.2.6 Power Frequency Magnetic Field Immunity
The tape drive meets the magnetic field immunity limits per EN 61000–4–8: 1993 listed in
Table 8-12
.
Table 8-10.
Surge Immunity Limits
Specification
Performance Criteria
Common/Differential Mode
AC Mains 2 kV / 1 kV
No operator intervention
(soft recoverable errors allowed)
Table 8-11.
Conducted Immunity Limits
Specification
Performance Criteria
0.150 to 80 MHz, 1 kHz (80% AM), 3V
No errors allowed
Table 8-12.
Magnetic Field Immunity Limits
Specification
Performance Criteria
50 Hz, 10 Amps per meter (A/m)
No errors allowed
±
±
Содержание ValueLoader DLT VS160
Страница 6: ...DLT VS160 Product Specification vi September 2004 81 81275 01...
Страница 10: ...Table of Contents DLT VS160 Product Specification x September 2004 81 81275 01 REV A02 Notes...
Страница 14: ...List of Tables DLT VS160 Product Specification xiv September 2004 81 81275 01 REV A02 Notes...
Страница 16: ...List of Figures DLT VS160 Product Specification xvi September 2004 81 81275 01 REV A02 Notes...
Страница 54: ...Consumer Bulletin Scheme DLT VS160 Product Specification 9 2 September 2004 81 81275 01 REV A02 Notes...
Страница 61: ......