20
Variables and Traps Quick Reference
Table 5
Status Traps
Event
Trap ID
Description
Physical Library Online
Status Change
101
Issued when the physical library is brought online or
taken offline.
Physical Library Door
Status Change
102
Issued when the physical library door has been
opened, closed, locked, or unlocked.
I/E Station Door Status
Change
103
Issued when a partition has been brought online or
taken offline.
RCU Ready
110
Issued when the robotics go from “not ready” to
“ready” state.
RCU Not Ready
111
Issued when the robotics go from “ready” to “not
ready” state. Traps 110 and 111 may occur as part of a
startup or shutdown procedure. If seen at another
time, it may indicate that the front door is open.
Logical Library Online
Status Change
204
Issued when a logical library, also known as a
partition, is brought online or taken offline.
RAS Status Change:
Connectivity
400
Issued when the status of the connectivity subsystem
changes, which includes the I/O management unit, I/O
blades, and other components. This may indicate a
change to “good” status, so check the return value for
required action. If the return value shows an issue, use
the LMC to determine the corrective actions.
RAS Status Change:
Control
401
Issued when the status of the control subsystem
changes, which includes system firmware, the
operator panel, and the MCB, RCU, and other control
blades. If the return value shows an issue, use the
LMC to determine the corrective actions.
RAS Status Change:
Cooling
402
Issued when the status of the cooling subsystem
changes. If the return value shows an issue, use the
LMC to determine the corrective actions.
RAS Status Change:
Drives and Media
403
Issued when the status of the drives and/or media
(including drive brick firmware) changes. If the return
value shows an issue, use the LMC to determine the
corrective actions.
RAS Status Change:
Power
404
Issued when the status of the power subsystem
changes. If the return value shows an issue, use the
LMC to determine the corrective actions.
RAS Status Change:
Robotics
405
Issued when the status of the robotics subsystem
changes. If the return value shows an issue, use the
LMC to determine the corrective actions.
Startup Sequence
Completed
500
Indicates the library startup sequence has completed.
Shutdown Sequence
Completed
501
Indicates the library shutdown sequence has
completed.