background image

Scalar i2000 Basic SNMP Reference Guide

1

About This Guide and Your Product

This reference guide describes the basic usage of the Simple Network Management Protocol (SNMP) to 
acquire alert information from the Scalar® i2000 library. Focus is placed on the most critical information 
available through Traps and Management Information Base (MIB) queries. For information about the Scalar 
i2000 library, itself, refer to the 

Scalar i2000 User’s Guide

. For information on integrating MIBs into a SNMP 

management application, contact your software vendor.

The information presented in this document represents the most commonly requested MIB objects and 
SNMP Traps needed to monitor the Scalar i2000 from a network management tool. For more information 
about the Scalar i2000 MIBs, contact technical support.

This basic SNMP reference is written for library customers, partners, third party management software 
developers, and other parties interested in integrating the Scalar i2000 library with commercial management 
frameworks.

This document assumes the reader has a working knowledge of SNMP. The reader should be able to 
compile a MIB on their specific framework application, perform SNMP GET operations, as well as 
understand how to collect Traps and filter them for information.

Explanation of Symbols and Notes

The following symbols appear throughout this document to highlight important information. 

WARNING

INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH, IF NOT 
AVOIDED, COULD RESULT IN DEATH OR BODILY INJURY.

CAUTION

Indicates a situation that may cause possible damage to equipment, loss of 
data, or interference with other equipment.

Note

Indicates important information that helps you make better use of your system.

Содержание Scalar i2000

Страница 1: ...6 01159 03 Scalar i 2000 B a s i c S N M P R e f e r e n c e G u i d e B a s i c S N M P R e f e r e n c e G u i d e Quantum Scalar i2000 Library Quantum Scalar i2000 Library...

Страница 2: ...t 2007 by Quantum Corporation All rights reserved Your right to copy this manual is limited by copyright law Making copies or adaptations without prior written authorization of Quantum Corporation is...

Страница 3: ...ueries 6 3 Library Identification 7 Product Name 7 Logical Library Name 7 4 Library Status and Health 9 Drive Online Offline Status 9 Drive Overall Health 10 Physical Library Online Offline State 10 R...

Страница 4: ...RAS System Status Change Traps 14 Trap 400 connectivityGroupStatusChange 14 Trap 401 controlGroupStatusChange 14 Trap 402 coolingGroupStatusChange 14 Trap 403 drivesAndMediaGroupStatusChange 14 Trap 4...

Страница 5: ...ar i2000 MIBs contact technical support This basic SNMP reference is written for library customers partners third party management software developers and other parties interested in integrating the S...

Страница 6: ...m support Scalar i2000 User s Guide 6 00421 xx ADIC Management Console User s Guide 6 00064 xx Note Release Notes are also available for this product The Release Notes describe changes to your system...

Страница 7: ...cluding answers to frequently asked questions FAQs You can also access software firmware and drivers through this site For further assistance or if training is desired contact Quantum For the most upd...

Страница 8: ...4 About This Guide and Your Product...

Страница 9: ...on the Scalar i2000 The MIB variables described in this document are the only ones supported by Quantum for external management of the library All other variables in the MIB are for internal use only...

Страница 10: ...gather status information about specific components of the library Frequent MIB queries are not required however since the SNMP agent is event driven GETs must also include an instance number This in...

Страница 11: ...and it is unique for the entire library Quantum recommends querying the Product Name so that the framework application will list the type of library being monitored Logical Library Name OID 1 3 6 1 4...

Страница 12: ...8 Library Identification...

Страница 13: ...s variable indicates whether a drive is varied on or varied off Instance There will be one instance for every physical drive in the library Query the specific instance that you need to access Drives a...

Страница 14: ...ary Query the specific instance that you need to access Drives are listed in sequential order See Table 1 on the previous page for details on interpreting the format of a drive instance ID Alerted by...

Страница 15: ...onDoorStatus Type INTEGER Values open 1 closed 2 closedAndLocked 3 closedAndUnlocked 4 controllerFailed 5 Description The state of the Import Export station door is returned by the phIeStationDoorStat...

Страница 16: ...ble provides a concise way to assess the health of the library s subsystems The library functionality is divided into six status groups connectivity control cooling drives and media power and robotics...

Страница 17: ...s shutdown sequence which includes reboot and shutdown ADIC Management MIB These informational traps are defined in the ADIC Management MIB Each is issued with enterprise OID management which resolves...

Страница 18: ...sChange The state of the connectivity hardware software has changed Trap 401 controlGroupStatusChange The state of the control hardware software has changed Trap 402 coolingGroupStatusChange The state...

Страница 19: ...000 Basic SNMP Reference Guide 15 Trap 404 powerGroupStatusChange The state of the power hardware software has changed Trap 405 roboticsGroupStatusChange The state of the robotics hardware software ha...

Страница 20: ...16 SNMP Traps...

Страница 21: ...of system components with identification and status for each Traps for a changed configuration added and removed components Library startup and shutdown traps ADIC Management MIB The ADIC Management M...

Страница 22: ...e Scalar i2000 MIBs reference the following SNMP standard MIBs RFC 1155 SMI RFC 1212 RFC 1213 MIB RFC 1215 These MIBs are necessary for accurate compilation of the Scalar i2000 MIBs and should be incl...

Страница 23: ...use the LMC to determine what RAS tickets have been generated for the drive Physical Library Online Offline Status 200 20 80 10 1 5 Indicates if the library is online or offline Use the LMC to confirm...

Страница 24: ...turn value for required action If the return value shows an issue use the LMC to determine the corrective actions RAS Status Change Control 401 Issued when the status of the control subsystem changes...

Страница 25: ...y identification 7 logical library name 7 product name 7 Library Management Console LMC 5 6 20 library status and health 9 drive online offline status 9 drive overall health 10 I E station door status...

Страница 26: ...ed 13 startupSequenceCompleted 13 symbols and notes explained 1 T training contact Quantum 3 Trap 101 13 Trap 102 13 Trap 103 13 Trap 110 13 Trap 111 14 Trap 400 14 Trap 401 14 Trap 402 14 Trap 403 14...

Отзывы: