Quantum Scalar 50 TC2201 iSCSI Bridge Upgrade Instructions
81-81792-01 A01
July 2007
8
TC2201 Upgrade Procedure
Installing the Ethernet
Cables
0
Scalar 50 libraries with an installed TC2201 iSCSI bridge must have the
following Ethernet connection:
1
Connect a cross-over cable between the right port of the library system
controller board (SCB) and the TC2201 (see
figure 7
).
Figure 7 Scalar Ethernet
Connection
Installing SCSI Cables
0
The SCSI cable installation procedure differs depending on the type of tape
drive installed. Refer to the following sections for installing the SCSI cables:
•
Installing SCSI Cables with Full Height Tape Drives
•
Installing SCSI Cables with Half-Height Tape Drives
Installing SCSI Cables with Full Height Tape Drives
0
Use the following procedure to connect the SCSI cables and terminators to the
tape drives and TC2201.
• SCSI connectors 0 through 1 on the TC2201 are used to connect to the
system controller board and tape drives 1 through 2.
To cable a TC2201 bridge to the tape drive(s):
1
To connect the SCSI cables from the TC2201 to the tape drives (see
figure 10
and
figure 9
):
a
Connect a SCSI cable (VHDC 68-pin to HD 68-pin) from the top port
of the system controller board to Port 0 on the TC2201.
b
Connect a SCSI cable (VHDC 68-pin to HD 68-pin) from the bottom
port of the system controller board to the upper port of tape drive 1.
c
Install a terminator on the bottom port of tape drive 1.
Cross-over cable
TC2201
SCB (right port)