Chapter 4 Service Instructions
40
Models QT-740 & QT-750 - Service Manual
6. Loosen two (2) bolts securing Sync Belt Switch to Sync Belt
Switch Bracket and remove Sync Belt Switch and set aside. (Do
not disconnect switch wires).
7. Loosen nut on Belt Tensioner to create slack in belt (see Figure
18). If necessary, remove Belt Tensioner to achieve sufficient
slack for belt removal.
8. Loosen two (2) 1/4-20 socket head cap screws securing Ball
Screw Mounting Block at pulley end of Lead Screw to Base Plate
(see Figure 18). Gently tap Block to remove it from Lead Screw.
9. Remove Sync Belt from pulleys.
10. Install replacement Sync Belt on pulleys.
11. Verify the distance between Ball Nut Blocks and center Ball Screw
Mounting Blocks (see Figure 19) are equal (±0.003"). If not,
rotate either shaft until distances are equal (within tolerance).
This is to ensure equal torque on both Lead Screws.
12. Install Ball Screw Mounting Block on pulley end of Lead Screw
and secure to Table Base Plate using two (2) 1/4-20 socket head
cap screws.
SYNC BELT
SWITCH
BRACKET
Figure 18. Location of Sync Belt Switch Bracket and Tensioner
BELT
TENSIONER
Содержание QT-740
Страница 4: ...Revision History ii Models QT 740 QT 750 Service Manual THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 7: ...Chapter 1 1 SPECIFICATIONS...
Страница 8: ...2...
Страница 13: ...Chapter 7 2 ASSEMBLY INSTALLATION...
Страница 14: ...8...
Страница 29: ...Chapter 23 3 THEORY OF OPERATION...
Страница 30: ...24...
Страница 38: ...Chapter 3 Theory of Operation 32 Models QT 740 QT 750 Service Manual THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 39: ...Chapter 33 4 SERVICE INSTRUCTIONS...
Страница 40: ...34...
Страница 57: ...Chapter 4 Service Instructions 51 Models QT 740 QT 750 Service Manual...
Страница 58: ...Chapter 51 5 DIAGRAMS...
Страница 59: ...52...
Страница 62: ...Chapter 5 Diagrams Models QT 740 QT 750 Service Manual 55 Figure 28 4 Way Table Control Board A1 AY40 017T...