Quantum PX500 Series FC1202 Upgrade Instructions
81-81351-01 C01
April 2006
24
FC1202 Upgrade Procedure
11
Figure 21
displays the current mapping for the Fibre port. Check
the map display at the top of the window for FC port 0. The display
should show the first pair of tape drives from SCSI bus 0 and 1
along with a robot (changer) if this is the first bridge in the card
cage.
Figure 21 Mapped SCSI
Devices
12
Click
Fill Map
to all attached SCSI drives and verify their presence in
the map.
13
Use
Delete Items Map Control
to remove devices that do not belong on
this Fibre Channel port to match the list in
step 11
.
14
Close the
Edit/View
window.
15
Click
Activate Mapping Changes
on
Mapping
page (see
figure 19
).
16
After activating the mapping options for the FC port, click
Reboot
from
the
Main
menu.
The
System Reboot
screen displays (see
figure 22
).
Mapped SCSI
devices