Quantum PX500 Series FC1202 Upgrade Instructions
81-81351-01 C01
April 2006
FC1202 Upgrade Procedure
17
Installing SCSI
Jumper Cables
0
Use the following procedure to connect the SCSI jumper cables and
terminators to the tape drives and FC1202(s).
• SCSI connectors 0 through 1 on the first FC1202 are used to connect to
tape drives 0 through 1 and the library robotics controller.
• SCSI connectors 0 through 1 on the second FC1202 are used to connect to
tape drives 2 through 3, if present.
• SCSI connectors 0 through 1 on the third FC1202 are used to connect tape
drives 4 through 5, if present.
• SCSI connectors 0 through 1 on the fourth FC1202 are used to connect
tape drives 6 through 7, if present.
• SCSI connectors 0 through 1 on the fifth FC1202 are used to connect tape
drives 8 through 9, if present.
To cable a FC1202 bridge to the tape drive(s):
1
To connect the SCSI cables from the FC1202 to the tape drives, see
table 2
and
figure 14
.
Table 2 Cabling a FC1202
Bridge to the Tape Drives
Caution:
Use care when handling the fibre optic cables. Do not
crimp or bend the cables.
Tape Drive Connection/
System Controller Board
FC1202 Connections/ Tape
Drive Termination
System controller board (top
port)
Port 0 on first FC1202
System controller board
(bottom port)
Tape Drive 1, upper port
Tape drive 1, lower port
Terminator
Tape drive 2, upper port
Port 1 on first FC1202
Ethernet port
Fibre Channel port
SCSI port 0
SCSI port 1