Chapter 2 Installing the Library
Configuring the Library
Quantum|ATL PowerStor L200 Series Library User’s Guide
19
If all the POST tests are completed successfully, and the drive and
library are initialized, the library is ready for operation. If the tests
did not complete, run the POST again; if the tests are still not
complete, the library needs service.
Configuring the Library
2
Configuration consists of verifying that the library and the internal
drive have the correct SCSI ID settings. The system uses SCSI IDs
to identify or address devices, such as the library controller and the
tape drive on the SCSI bus.
If the library is one of multiple SCSI devices on the bus, be sure to
use a SCSI ID that is unique from any other device or system ID on
the SCSI bus (see
table 2
).
Table 2 SCSI ID
Default Settings
Verifying the SCSI
Settings
2
To view the current SCSI ID settings using the OCP (see
figure 1
):
1
Press
Select
until the message
SCSI ID?
is displayed.
2
Press
Next
to enter the SCSI ID menu and display the message
View ID?.
3
Press
Enter
to view all the SCSI IDs.
Note:
To rerun the POST, turn off the library. Wait ten seconds,
then turn the library power on again.
SCSI ID
Device
1
Tape drive
0
Library controller
Содержание PowerStor L200
Страница 1: ...Quantum ATL PowerStor L200 Series Library User s Guide 6322500 04 Ver 4 Rel 0...
Страница 7: ...Contents Quantum ATL PowerStor L200 Series Library User s Guide vii Glossary 87 Index 93...
Страница 8: ...Contents viii Quantum ATL PowerStor L200 Series Library User s Guide...
Страница 10: ...Figures x Quantum ATL PowerStor L200 Series Library User s Guide...
Страница 108: ...Glossary 92 Quantum ATL PowerStor L200 Series Library User s Guide...
Страница 112: ...Index 96 Quantum ATL PowerStor L200 Series Library User s Guide...