Chapter 2 Installing the Library
Running the Power-on Self-test
18
Quantum|ATL PowerStor L200 Series Library User’s Guide
Running the Power-on Self-test
2
Run the power-on self-test (POST) to verify proper system
installation.
Turn on the library using the power switch on the back of the
library. The POST runs automatically. The following message is
displayed:
PowerStor POST
Table 1
lists the tests that are run during POST along with the OCP
pass or error messages associated with these tests.
Table 1 POST Pass/
Error Messages
Next the drive and the library are initialized. If the optional bar
code reader is present (and the bar code enable mode is set), the
cartridge bar code labels are read. The OCP buttons are not active
until the
Library Idle
message is displayed on the library OCP.
The following messages are displayed:
Library INIT
Library Idle
POST Test
(Description)
Messages
Pass
Error
ROM EDC
(flash ROM
EDC)
PowerStor POST 1 EDC
POST Error in ROM
EDC
Micro RAM
(microprocessor local
RAM test)
PowerStor POST 2 Micro
RAM
POST Error in
Micro RAM
UART
(QUART test)
PowerStor POST 3 UART
POST Error in UART
Other
PowerStor POST 4 Other
POST Error in
Other
Содержание PowerStor L200
Страница 1: ...Quantum ATL PowerStor L200 Series Library User s Guide 6322500 04 Ver 4 Rel 0...
Страница 7: ...Contents Quantum ATL PowerStor L200 Series Library User s Guide vii Glossary 87 Index 93...
Страница 8: ...Contents viii Quantum ATL PowerStor L200 Series Library User s Guide...
Страница 10: ...Figures x Quantum ATL PowerStor L200 Series Library User s Guide...
Страница 108: ...Glossary 92 Quantum ATL PowerStor L200 Series Library User s Guide...
Страница 112: ...Index 96 Quantum ATL PowerStor L200 Series Library User s Guide...