Quantum DX-Series System Unpacking and Installation Instructions
Document 6513502-06 A01
October 2006
Installing the DX-Series System
25
Figure 18 Sliding the Fibre
Channel Switch into the
Support Brackets
6
Install 2U blank-off plate in front of rack covering the space taken by the
Fibre Channel switch and Ethernet switch.
Repeat this procedure for an additional Fibre Channel switch in a second
rack to support more than 8 storage arrays.
Installing the Ethernet
Switch (DX100 Only)
0
To install the Ethernet switch:
1
Install the mounting ears on to the Ethernet switch with three PHILLIPS
screws on each side (see
figure 19
).
Note:
Install two 10-32 x .50 in. screws in the rack under the right
and left top corners of the 2U blank-off plate.
Note:
To accommodate the Ethernet cabling connections, the Ethernet
switch must be installed with the ports facing the back of the rack.
Fibre Channel switch
Switch may be visually different